文献速递前列腺癌

根治性前列腺切除术中切缘评估:共聚焦显微镜与冰冻切片分析对比

Evaluation of margins during radical prostatectomy: confocal microscopy vs frozen section analysis.
PubMed 文献 · BJU Int · 2024-06-18

研究在45例机器人辅助根治性前列腺切除术患者的54处切缘中,对比离体荧光共聚焦显微镜(FCM)与术中冰冻切片(IFS)分析,以最终病理为参照。高年资病理医师FCM判读敏感度70.5%、特异度91.8%、阳性预测值80.0%、阴性预测值87.1%;IFS分别为88.2%、100%、100%、94.8%。结论认为FCM可行、可靠,但性能似乎不及IFS这一既定标准。

要点

  • 高年资病理医师FCM判读敏感度70.5%、特异度91.8%、阳性预测值80.0%、阴性预测值87.1%。
  • IFS分析敏感度88.2%、特异度100%、阳性预测值100%、阴性预测值94.8%。
  • FCM与IFS之间一致性按四类结果从中等(κ=0.62)到强(κ=0.86)。

核心结论

  • 离体FCM评估前列腺切缘似乎可行且可靠,读者间一致性鼓励其在日常实践中广泛使用。
  • 然而,截至目前,FCM的性能与既定标准(IFS分析)相比似乎不达标。

研究设计与样本

  • 对45例接受机器人辅助根治性前列腺切除术(RARP)患者的54处切缘进行分析:离体FCM、IFS分析和最终病理。
  • FCM切缘由两名不同病理医师(经验10年 vs 超过30年)判读为强阴性、可能阴性、可疑、可能阳性或强阳性。
  • 分析包括病理医师间一致性(Cohen's κ)、FCM的敏感度、特异度、阳性预测值和阴性预测值,以及FCM与IFS的一致性(Cohen's κ);所有分析评估FCM结果的四种组合。

主要发现

  • 离体FCM病理医师间一致性按四类结果从中等(κ=0.74)到几乎完美(κ=0.90)。
  • 高年资病理医师在离体FCM达到最佳平衡:敏感度70.5%、特异度91.8%、阳性预测值80.0%、阴性预测值87.1%。
  • IFS分析的敏感度、特异度、阳性预测值和阴性预测值分别为88.2%、100%、100%、94.8%。
  • 离体FCM与IFS分析之间的一致性按四类结果从中等(κ=0.62)到强(κ=0.86)。

关键数值与推荐

  • 离体FCM(高年资病理医师):敏感度70.5%、特异度91.8%、阳性预测值80.0%、阴性预测值87.1%。
  • IFS分析:敏感度88.2%、特异度100%、阳性预测值100%、阴性预测值94.8%。
  • FCM病理医师间一致性:κ=0.74至κ=0.90(按四类结果)。
  • FCM与IFS一致性:κ=0.62至κ=0.86(按四类结果)。

临床怎么用

  • 作者认为离体FCM评估前列腺切缘似乎可行且可靠,读者间一致性鼓励其在日常实践中广泛使用。
  • 作者同时指出,截至目前FCM的性能与既定标准IFS分析相比似乎不达标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To test the performance of ex vivo fluorescence confocal microscopy (FCM; Vivascope 2500M-G4), as compared to intra-operative frozen section (IFS) analysis, to evaluate surgical margins during robot-assisted radical prostatectomy (RARP), with final pathology as the reference standard. METHODS: Overall, 54 margins in 45 patients treated with RARP were analysed with: (1) ex vivo FCM; (2) IFS analysis; and (3) final pathology. FCM margins were evaluated by two different pathologists (experienced [M.I.: 10 years] vs highly experienced [G.R.: >30 years]) as strongly negative, probably negative, doubtful, probably positive, or strongly positive. First, inter-observer agreement (Cohen's κ) between pathologists was tested. Second, we reported the sensitivity, specificity, positive predictive (PPV) and negative predictive value (NPV) of ex vivo FCM. Finally, agreement between ex vivo FCM and IFS analysis (Cohen's κ) was reported. For all analyses, four combinations of FCM results were evaluated. RESULTS: At ex vivo FCM, the inter-observer agreement between pathologists ranged from moderate (κ = 0.74) to almost perfect (κ = 0.90), according to the four categories of results. Indeed, at ex vivo FCM, the highly experienced pathologist reached the best balance between sensitivity (70.5%) specificity (91.8%), PPV (80.0%) and NPV (87.1%). Conversely, on IFS analysis, the sensitivity, specificity, PPV and NPV were, respectively, 88.2% vs 100% vs 100% vs 94.8%. The agreement between the ex vivo FCM and IFS analyses ranged from moderate (κ = 0.62) to strong (κ = 0.86), according to the four categories of results. CONCLUSION: Evaluation of prostate margins at ex vivo FCM appears to be feasible and reliable. The agreement between readers encourages its widespread use in daily practice. Nevertheless, as of today, the performance of FCM seems to be sub-par when compared to the established standard of care (IFS analysis).

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Musi G, Mistretta FA, Ivanova M, et al. Evaluation of margins during radical prostatectomy: confocal microscopy vs frozen section analysis. BJU Int. 2024. PMID: 38890817. doi:10.1111/bju.16441

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。