文献速递泌尿系结石

MOSES技术的钬钇铝石榴石激光在仰卧位迷你经皮肾镜取石术中比铥光纤激光更高效

Holmium:yttrium-aluminium-garnet laser with MOSES technology is more efficient than thulium fibre laser in supine mini-percutaneous nephrolithotomy.
PubMed 文献 · BJU Int · 2024-05-26

本研究回顾性比较了2021年8月至2023年5月间接受仰卧位迷你经皮肾镜取石术的患者,使用MOSES技术的钬钇铝石榴石激光与铥光纤激光的效果。共纳入100例患者,钬激光组51例,铥光纤激光组49例。两组结石清除率无显著差异,但钬激光组所用能量和时间更少,消融效率更高(P<0.05),总手术时间更短(P<0.05)。

要点

  • 钬激光组与铥光纤激光组在结石清除率各分类中均无显著差异。
  • 钬激光组所用能量和时间更少,消融效率更高(P<0.05)。
  • 钬激光组总手术时间更短(P<0.05)。

核心结论

  • 尽管术后结石清除率相当,但本研究支持在迷你经皮肾镜取石术中,钬钇铝石榴石激光相比铥光纤激光具有更短的手术时间和更高的术中激光效率。

研究设计与样本

  • 回顾性综述,纳入2021年8月至2023年5月期间接受仰卧位迷你经皮肾镜取石术的患者,比较钬钇铝石榴石激光(Lumenis Pulse P120H™ with MOSES technology,120W;Boston Scientific®)与铥光纤激光(Soltive SuperPulsed Thulium Fibre [SPTF],60W;Olympus®)。
  • 排除标准为尿流改道、同时使用超过1种激光平台、使用任何其他形式的碎石以及输尿管结石。
  • 共100例患者符合纳入标准,其中钬激光组51例,SPTF激光组49例。

主要发现

  • 两组人口统计学或结石特征无显著差异。
  • 钬激光组所用能量和时间更少,消融效率更高(P<0.05),总手术时间更短(P<0.05)。
  • 总体而言,钬激光组与SPTF组在任何分类的结石清除率均无差异:无碎片相对风险(RR)0.81,95%置信区间(CI)0.59-1.12,P=0.21;碎片<2 mm RR 0.86,95% CI 0.67-1.10,P=0.23;碎片<4 mm RR 0.96,95% CI 0.80-1.15,P=0.67。

关键数值与推荐

  • 结石清除率通过术后第一天的计算机断层扫描确定,并表示为无结石碎片、无大于2 mm的碎片或无大于4 mm的碎片。
  • 无碎片:RR 0.81,95% CI 0.59-1.12,P=0.21。
  • 碎片<2 mm:RR 0.86,95% CI 0.67-1.10,P=0.23。
  • 碎片<4 mm:RR 0.96,95% CI 0.80-1.15,P=0.67。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To address the paucity of literature comparing outcomes achieved with utilisation of the high-power holmium:yttrium-aluminium-garnet (Ho:YAG) laser with MOSES technology vs those achieved with the thulium fibre laser (TFL) in mini-percutaneous nephrolithotomy (PCNL). METHODS: A retrospective review was performed of patients undergoing supine mini-PCNL between August 2021 and May 2023. Exclusion criteria were urinary diversion, simultaneous utilisation of >1 laser platform, use of any other form of fragmentation, and ureteric stones. The Ho:YAG platform (Lumenis Pulse P120H™ with MOSES technology, 120W; Boston Scientific®) and the TFL (Soltive SuperPulsed Thulium Fibre [SPTF], 60W; Olympus®) were compared. Data on stone-free rate (SFR) were determined by computed tomography performed on the first postoperative day and presented as absence of stone fragments, no fragments larger than 2 mm, or no fragments larger than 4 mm. RESULTS: A total of 100 patients met the inclusion criteria, 51 mini-PCNLs with the Ho:YAG laser and 49 with the SPTF laser. No significant differences in demographics or stone characteristics were detected between the two groups. The Ho:YAG laser utilised less energy and time, resulting in higher ablation efficiency (P < 0.05) and less total operating time (P < 0.05). Overall, there was no difference in SFR in any category between the Ho:YAG group and the SPTF group (no fragments: relative risk [RR] 0.81, 95% confidence interval [CI] 0.59-1.12, P = 0.21; fragments <2 mm: RR 0.86, 95% CI 0.67-1.10, P = 0.23; fragments <4 mm: RR 0.96, 95% CI 0.80-1.15, P = 0.67). CONCLUSIONS: Although we observed an equivalent postoperative SFR, this study supports a shorter operating time and greater intra-operative laser efficiency with the Ho:YAG laser over the SPTF laser in mini-PCNL.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Vergamini LB, Ito W, Choi B N, et al. Holmium:yttrium-aluminium-garnet laser with MOSES technology is more efficient than thulium fibre laser in supine mini-percutaneous nephrolithotomy. BJU Int. 2024. PMID: 38797721. doi:10.1111/bju.16392

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。