文献速递前列腺增生与排尿功能障碍男科与性医学

男性吊带手术中膀胱镜括约肌评估的观察者内与观察者间可靠性

Intra/inter-observer reliability of cystoscopic sphincter evaluation in men undergoing sling surgery.
PubMed 文献 · BJU Int · 2024-04-16

本研究前瞻性拍摄因尿失禁行吊带手术男性的膀胱镜检,将匿名录像随机两次提供给26名观察者(医学生、住院医师、执业0-5、5-10、>10年的泌尿科医师)评分。结果显示观察者内ICC为0.54-0.60,观察者间ICC为0.31-0.53,结论认为膀胱镜括约肌评估(CSE)的观察者内与观察者间可靠性差,不能为临床评估提供有价值的信息。

要点

  • 观察者内可靠性ICC:医学生0.54、住院医师0.58、泌尿科医师0.60。
  • 观察者间可靠性ICC范围0.31-0.53,泌尿科医师之间最低为0.31。
  • CSE可靠性差,不应脱离患者特征单独考虑。

核心结论

  • 本研究显示膀胱镜括约肌评估(CSE)的观察者内与观察者间可靠性均差。

研究设计与样本

  • 前瞻性研究,由两名专家泌尿科医师按标准场景对尿失禁患者的膀胱镜检进行拍摄记录,匿名录像随机两次提供给26名观察者(医学生、泌尿科住院医师及执业年限0-5年、5-10年、>10年的泌尿科医师)在不了解患者特征的情况下评估并评分。

主要发现

  • 共37段录像被26名观察者两次评分。
  • 观察者内可靠性ICC:医学生0.54(中等)、住院医师0.58(中等)、泌尿科医师0.60(显著)。
  • 按经验分层后,经验>10年的专家之间一致性最低。
  • 观察者间可靠性ICC范围为0.31至0.53,泌尿科医师之间ICC最低为0.31。

临床怎么用

  • 作者认为,根据这些结果,CSE不能为临床评估增加有价值的信息,在此情况下不应脱离患者特征单独考虑。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To assess the intra/inter-observer reliability of cystoscopic sphincter evaluation (CSE) in men undergoing sling surgery for urinary incontinence and if possible to evaluate its correlation with the final clinical decision. PATIENTS AND METHODS: Two expert urologists prospectively filmed and recorded, incontinent patient's cystoscopies according to a standard scenario. Anonymised recordings where randomly offered to the same observer twice. The observers (medical students, urology residents and full urologist with 0-5, 5-10, >10 years of practice, respectively) were asked to assess and score the recordings without knowing any of the patients' characteristics. RESULTS: In total, 37 recordings were scored twice by the 26 observers. The intraclass correlation coefficient (ICC) for intra-observer reliability of the CSE was 0.54 (moderate), 0.58 (moderate) and 0.60 (substantial) for medical students, residents, and urologists, respectively. However, when stratifying observers according to their experience, the lowest agreement values were found between experts with >10 years of experience. The inter-observer reliability for the CSE ICCs ranged between 0.31and 0.53, with the lowest ICC value observed between urologists (0.31). CONCLUSIONS: The study demonstrates poor intra- and inter-observer reliability of the CSE. According to these results, a CSE does not add valuable information to the clinical evaluation. In this scenario, it should not be considered in isolation from the patient's characteristics.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Tutolo M, Laenen A, Rosiello G, et al. Intra/inter-observer reliability of cystoscopic sphincter evaluation in men undergoing sling surgery. BJU Int. 2024. PMID: 38627205. doi:10.1111/bju.16353

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。