文献速递肾癌与肾肿瘤

全自动版本的临床验证肾脏测量评分在预测效用上优于人工评分

Fully Automated Versions of Clinically Validated Nephrometry Scores Demonstrate Superior Predictive Utility versus Human Scores.
PubMed 文献 · BJU Int · 2024-02-11

本研究对300例疑似肾癌患者的术前CT开发人工智能图像处理方法,自动生成C-Index、PADUA和肿瘤接触表面积三种肾脏测量评分,并与人工评分比较。结果显示AI评分与人工评分一致性显著(R 0.574–0.828,均P<0.001),且在所有考察结局上AI评分等效或优于人工评分。作者认为经验证后AI评分可在诊疗现场自动提供以辅助决策。

要点

  • AI自动生成的C-Index、PADUA和肿瘤接触表面积评分与人工评分一致性显著(R 0.574–0.828,均P<0.001)。
  • AI评分在所有考察结局上等效或优于人工评分,包括高级别组织学、高分期肿瘤、惰性肿瘤、病理肿瘤坏死及根治性肾切除术(对比部分肾切除术)手术方式。
  • 作者认为经验证后,AI生成的肾脏测量评分可从术前CT自动提供给临床医生和患者,以辅助决策。

核心结论

  • 全自动AI生成的C-Index、PADUA和肿瘤接触表面积肾脏测量评分与人工评分相似,并能预测多种有意义的结局。
  • 作者认为经验证后,AI生成的肾脏测量评分可从术前CT自动提供给临床医生和患者,以辅助决策。

研究设计与样本

  • 从544例连续因疑似肾癌接受手术切除的患者中识别出300例有术前动脉早期增强CT的患者。
  • 采用深度神经网络自动分割肾脏和肿瘤,再用几何算法测量C-Index、PADUA和肿瘤接触表面积肾脏测量评分的各组成部分。
  • 人工评分由对AI评分不知情的医务人员独立计算;采用线性回归评估AI与人工评分一致性,采用逻辑回归和受试者工作特征曲线分析评估预测能力。

主要发现

  • 中位(四分位距)年龄为60(51–68)岁,40%为女性。
  • 中位肿瘤大小为4.2 cm,91.3%为恶性肿瘤。
  • 27%的肿瘤为高分期,37%为高级别,63%的患者接受了部分肾切除术。
  • 人工与AI评分在线性回归分析上一致性显著(R范围为0.574至0.828,均P<0.001)。
  • AI生成的评分在所有考察结局上等效或优于人工评分,包括高级别组织学、高分期肿瘤、惰性肿瘤、病理肿瘤坏死及根治性肾切除术(对比部分肾切除术)手术方式。

关键数值与推荐

  • AI与人工评分线性回归R范围为0.574至0.828,均P<0.001。

临床怎么用

  • 作者认为经验证后,AI生成的肾脏测量评分可从术前CT自动提供给临床医生和患者,以辅助决策。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To automate the generation of three validated nephrometry scoring systems on preoperative computerised tomography (CT) scans by developing artificial intelligence (AI)-based image processing methods. Subsequently, we aimed to evaluate the ability of these scores to predict meaningful pathological and perioperative outcomes. PATIENTS AND METHODS: A total of 300 patients with preoperative CT with early arterial contrast phase were identified from a cohort of 544 consecutive patients undergoing surgical extirpation for suspected renal cancer. A deep neural network approach was used to automatically segment kidneys and tumours, and then geometric algorithms were used to measure the components of the concordance index (C-Index), Preoperative Aspects and Dimensions Used for an Anatomical classification of renal tumours (PADUA), and tumour contact surface area (CSA) nephrometry scores. Human scores were independently calculated by medical personnel blinded to the AI scores. AI and human score agreement was assessed using linear regression and predictive abilities for meaningful outcomes were assessed using logistic regression and receiver operating characteristic curve analyses. RESULTS: The median (interquartile range) age was 60 (51-68) years, and 40% were female. The median tumour size was 4.2 cm and 91.3% had malignant tumours. In all, 27% of the tumours were high stage, 37% high grade, and 63% of the patients underwent partial nephrectomy. There was significant agreement between human and AI scores on linear regression analyses (R ranged from 0.574 to 0.828, all P < 0.001). The AI-generated scores were equivalent or superior to human-generated scores for all examined outcomes including high-grade histology, high-stage tumour, indolent tumour, pathological tumour necrosis, and radical nephrectomy (vs partial nephrectomy) surgical approach. CONCLUSIONS: Fully automated AI-generated C-Index, PADUA, and tumour CSA nephrometry scores are similar to human-generated scores and predict a wide variety of meaningful outcomes. Once validated, our results suggest that AI-generated nephrometry scores could be delivered automatically from a preoperative CT scan to a clinician and patient at the point of care to aid in decision making.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Wood AM, Abdallah N, Heller N, et al. Fully Automated Versions of Clinically Validated Nephrometry Scores Demonstrate Superior Predictive Utility versus Human Scores. BJU Int. 2024. PMID: 38343198. doi:10.1111/bju.16276

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。