文献速递前列腺增生与排尿功能障碍男科与性医学

51-60 cm H2O 人工尿道括约肌压力调节球囊:适应证与结局

The 51-60 cm H2O Artificial Urinary Sphincter Pressure Regulating Balloon: Indications and Outcomes.
PubMed 文献 · Urology · 2023-10-05

2005至2021年间,90例存在多种尿道危险因素的男性患者在接受人工尿道括约肌(AUS)植入时使用低压51-60 cm H2O压力调节球囊(PRB)治疗压力性尿失禁。中位随访46.6个月(范围6-146个月)后,4例(4.44%)发生需取出装置的侵蚀相关并发症,4例发生感染,3例因泵移位接受手术,1例报告来源不明的机械故障,30例因尿失禁接受修正手术。单变量分析未发现盆腔放疗史、AUS植入时年龄、阴茎假体(IPP)存在、既往AUS侵蚀或既往尿道成形术与袖套侵蚀、感染或修正手术存在显著关联。作者认为,低压51-60 cm H2O PRB可用于存在尿道危险因素的高危男性尿失禁患者,并发症(侵蚀、感染、机械故障)发生率低,并应被考虑作为此类患者的初始PRB。

要点

  • 90例有尿道危险因素的男性AUS植入时使用51-60 cm H2O低压PRB,中位随访46.6个月。
  • 侵蚀相关并发症需取出装置4例(4.44%),感染4例,泵移位手术3例,机械故障1例。
  • 30例因尿失禁接受修正手术;单变量分析未发现所查危险因素与侵蚀、感染或修正显著相关。

核心结论

  • 低压51-60 cm H2O PRB可用于存在尿道危险因素的男性尿失禁患者,侵蚀、感染和机械故障发生率低;尽管患者可能选择日后修正手术以改善控尿,作者认为51-60 cm H2O PRB应被考虑作为有尿道危险因素患者的初始PRB。

研究设计与样本

  • 2005至2021年间纳入90例存在多种尿道危险因素、接受AUS植入并以低压51-60 cm H2O PRB治疗压力性尿失禁的男性患者,回顾性分析人口学、PRB使用指征、围手术期数据和术后结局,采用Pearson卡方检验和Wilcoxon秩和检验分析与未来修正、侵蚀和机械故障的关联。

主要发现

  • 中位随访46.6个月(范围6-146个月)后,4例(4.44%)发生需取出装置的侵蚀相关并发症,4例发生感染,3例因泵移位接受手术,1例报告来源不明的机械故障。
  • 30例因尿失禁接受修正手术。
  • 4例侵蚀患者中,1例由医源性导尿所致,其余3例存在多种尿道危险因素。
  • 单变量分析未发现盆腔放疗史、AUS植入时年龄、IPP存在、既往AUS侵蚀或既往尿道成形术与袖套侵蚀、感染或修正手术存在显著关联。

临床怎么用

  • 作者认为,低压51-60 cm H2O PRB可用于存在尿道危险因素的男性尿失禁患者,并应被考虑作为此类患者的初始PRB。
  • 作者指出,患者可能选择日后接受修正手术以改善控尿。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To describe the role and long-term outcomes of using the 51-60cm H2O pressure regulating balloon (PRB) in male patients with an artificial urinary sphincter (AUS). METHODS: From 2005-2021, 90 patients with a variety of urethral risk factors underwent AUS placement with use of the low-pressure 51-60 cm H2O PRB to treat stress incontinence. Patient demographics, indication for use of the 51-60 cm H2O PRB, perioperative data, and postoperative outcomes were examined and Pearson's chi squared test and Wilcoxon rank sum test were used to identify associations with future revisions, erosion, and mechanical failure. RESULTS: Ninety patients were included in the study. After median follow-up of 46.6months (range: 6-146months), 4 (4.44%) patients developed an erosion-related complication that required device removal, 4 developed an infection, and 3 underwent surgery for pump relocation. One patient had a reported mechanical failure of unknown source. Thirty patients underwent revision surgery to reduce incontinence. Of the 4 patients with erosion, 1 was due to iatrogenic catheterization. The remaining 3 had numerous urethral risk factors. Univariate analysis was performed to identify predictors of cuff erosion, infection, and revision in patients with a 51-60 cm H2O PRB. No significant associations were found including prior pelvic radiation, age at AUS placement, presence of inflatable penile prosthesis (IPP), prior AUS erosion, or previous urethroplasty. CONCLUSION: The low-pressure 51-60 cm H2O PRB can be used in high-risk male patients with urinary incontinence with low rates of complications including erosion, infection, and mechanical failure. While patients may choose to undergo future revisional surgery to improve continence, the 51-60 cm H2O PRB should be considered as the initial PRB in patients with urethral risk factors.

来源:Urology,查看原文。版权归原作者所有。