文献速递前列腺增生与排尿功能障碍

脉冲波与连续波铥光纤激光前列腺剜除术(ThuFLEP)的围手术期结局比较

Pulsed-wave vs Continuous-wave Thulium Fiber Laser Enucleation of the Prostate (ThuFLEP): A Comparison of Perioperative Outcomes.
PubMed 文献 · Urology · 2023-05-29

本研究比较脉冲波与连续波铥光纤激光前列腺剜除术治疗良性前列腺增生的围手术期结局,238例患者中脉冲波组118例、连续波组120例。连续波组手术时间更短(61.5 vs 67.4分钟,P=0.04),其余指标两组相当。术后3个月两组排尿功能与性功能改善无显著差异。

要点

  • 连续波组手术时间较脉冲波组缩短(61.5 vs 67.4分钟,P=0.04)。
  • 剜除时间、剜除效率、导尿时间、冲洗量、住院时间及血红蛋白下降两组相当。
  • 术后3个月IPSS、Qmax、残余尿量、IIEF-5及PSA值两组无显著差异。

核心结论

  • 脉冲波与连续波铥光纤激光前列腺剜除术均能同等缓解下尿路症状,疗效高且安全。
  • 连续波组手术时间显著更短,但差异小、临床影响低。
  • 剜除时间、剜除效率、导尿时间、冲洗量、住院时间、血红蛋白与PSA下降、并发症率及性功能结局两组无差异。

研究设计与样本

  • 比较脉冲波与连续波铥光纤激光前列腺剜除术治疗良性前列腺增生的研究。
  • 共238例因良性前列腺增生导致下尿路症状的患者,脉冲波组118例,连续波组120例。
  • 记录术前前列腺体积、腺瘤体积、PSA及血红蛋白值。
  • 评估IPSS、Qmax、残余尿量及IIEF-5评分。
  • 记录手术时间、剜除时间、剜除效率、导尿时间、冲洗量、住院时间、血红蛋白下降及术后并发症,术后3个月评估排尿改善与性功能结局。

主要发现

  • 连续波组手术时间短于脉冲波组(61.5 vs 67.4分钟,P=0.04)。
  • 剜除时间脉冲波组50.2分钟 vs 连续波组53.3分钟(P=0.12)。
  • 剜除效率脉冲波组0.8 g/min vs 连续波组0.7 g/min(P=0.38)。
  • 导尿时间脉冲波组2.2天 vs 连续波组2.1天(P=0.29),冲洗量脉冲波组32.9 L vs 连续波组32.8 L(P=0.71),住院时间脉冲波组2.8天 vs 连续波组2.6天(P=0.29),血红蛋白下降脉冲波组0.38 g/dL vs 连续波组0.39 g/dL(P=0.53)。
  • 并发症率两组无显著差异;术后3个月IPSS、Qmax、残余尿量、IIEF-5及PSA值两组无显著差异。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare intra and early postoperative outcomes between pulsed-wave and continuous-wave Thulium Fiber Laser Enucleation of the Prostate (PW-ThuFLEP vs CW-ThuFLEP) for the treatment of benign prostatic hyperplasia. METHODS: 238 patients with lower urinary tract symptoms due to benign prostatic hyperplasia underwent PW-ThuFLEP (118 patients) vs CW-ThuFLEP (120 patients). Preoperative prostate volume, adenoma volume, prostate-specific antigen (PSA), and hemoglobin values were recorded. International Prostate Symptom Score (IPSS), maximum flow rate (Qmax), post-void residual volume, and International Index of Erectile Function-5 score (IIEF-5) were assessed. Operative time, enucleation time, enucleation efficiency, catheterization time, irrigation volume, hospital stay, hemoglobin drop, and postoperative complications were recorded. Micturition improvements and sexual outcomes were evaluated 3months after surgery. RESULTS: CW-ThuFLEP showed shorter operative time (61.5 vs 67.4 minutes, P = .04). Enucleation time (50.2 vs 53.3 minutes, P = .12), enucleation efficiency (0.8 vs 0.7 g/min, P = .38), catheterization time (2.2 vs 2.1days, P = .29), irrigation volume (32.9 vs 32.8L, P = .71), hospital stay (2.8 vs 2.6days, P = .29) and hemoglobin drop (0.38 vs 0.39 g/dL, P = .53) were comparable. No significant difference in complication rate was observed. At 3-month follow-up, the procedures did not show any significant difference in IPSS, Qmax, post-void residual volume, IIEF-5, and PSA value. CONCLUSION: PW-ThuFLEP and CW-ThuFLEP both relieve lower urinary tract symptoms equally, with high efficacy and safety. Operative time was significantly shorter with CW-ThuFLEP, but with a small difference with low clinical impact. Enucleation time, enucleation efficiency, catheterization time, irrigation volume, hospital stay, hemoglobin and PSA drop, complication rate, and sexual outcomes showed no differences.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Perri D, Mazzoleni F, Besana U, et al. Pulsed-wave vs Continuous-wave Thulium Fiber Laser Enucleation of the Prostate (ThuFLEP): A Comparison of Perioperative Outcomes. Urology. 2023. PMID: 37257589. doi:10.1016/j.urology.2023.05.013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。