人工智能在前列腺癌组织学识别与分级中诊断准确性的系统综述与Meta分析
该系统综述与Meta分析评估人工智能在前列腺癌组织学中的应用,纳入24项研究(约8000例前列腺活检和458例根治性前列腺切除术标本)。AI鉴别前列腺癌与良性增生的汇总敏感度为0.96、汇总特异度为0.95,SROC曲线AUC=0.99;Gleason分级准确度较低,敏感度77%–87%、特异度82%–90%。作者认为AI识别与分级准确度与专家病理医师相当。
要点
- AI鉴别前列腺癌与良性增生的汇总敏感度为0.96(I²=80.7%),汇总特异度为0.95(I²=86.1%)。
- Gleason分级AI准确度较低,敏感度77%–87%,特异度82%–90%。
- AI识别与分级准确度与专家病理医师相当,但卷积神经网络训练与调优困难耗时可能限制其进入常规实践。
核心结论
- AI在前列腺癌识别与分级中的准确度与专家病理医师相当。
- AI是有前景的方法,可能有若干临床应用,使病理报告更快捷和优化。
- AI进入常规实践可能受限于困难且耗时的卷积神经网络训练与调优。
研究设计与样本
- 系统综述与Meta分析,在3个数据库中系统检索文献。
- 最终样本包括24项研究,研究开展于2007年至2021年。
- 汇总约8000例前列腺活检和458例根治性前列腺切除术病例的数据。
- 主要结局为AI区分前列腺癌与良性增生的准确度;次要结局为AI确定Gleason分级和AI与病理医师之间一致性的准确度。
主要发现
- 前列腺癌诊断敏感度超过90%,范围为87%至100%;特异度范围为68%至99%。
- 总体准确度范围为83.7%至98.3%,AUC达到0.99。
- 采用Mantel-Haenszel法的Meta分析显示汇总敏感度为0.96(I²=80.7%),汇总特异度为0.95(I²=86.1%)。
- 汇总阳性似然比为15.3(I²=87.3%),汇总阴性似然比为0.04(I²=78.6%)。
- SROC曲线显示AUC=0.99。
关键数值与推荐
- AI鉴别前列腺癌与良性增生的汇总敏感度为0.96(I²=80.7%),汇总特异度为0.95(I²=86.1%)。
- 汇总阳性似然比为15.3(I²=87.3%),汇总阴性似然比为0.04(I²=78.6%)。
- Gleason分级AI敏感度范围为77%至87%,特异度范围为82%至90%。
临床怎么用
- 作者认为AI识别与分级准确度与专家病理医师相当,是有前景的方法,可能有若干临床应用,使病理报告更快捷和优化。
- 作者指出AI进入常规实践可能受限于困难且耗时的卷积神经网络训练与调优。
局限性
- AI进入常规实践可能受限于困难且耗时的卷积神经网络训练与调优。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Artificial intelligence (AI) is a promising tool in pathology, including cancer diagnosis, subtyping, grading, and prognostic prediction. METHODS: The aim of the study is to assess AI application in prostate cancer (PCa) histology. We carried out a systematic literature search in 3 databases. Primary outcome was AI accuracy in differentiating between PCa and benign hyperplasia. Secondary outcomes were AI accuracy in determining Gleason grade and agreement among AI and pathologists. RESULTS: Our final sample consists of 24 studies conducted from 2007 to 2021. They aggregate data from roughly 8000 cases of prostate biopsy and 458 cases of radical prostatectomy (RP). Sensitivity for PCa diagnostic exceeded 90% and ranged from 87% to 100%, and specificity varied from 68% to 99%. Overall accuracy ranged from 83.7% to 98.3% with AUC reaching 0.99. The meta-analysis using the Mantel-Haenszel method showed pooled sensitivity of 0.96 with I2 = 80.7% and pooled specificity of 0.95 with I2 = 86.1%. Pooled positive likehood ratio was 15.3 with I2 = 87.3% and negative - was 0.04 with I2 = 78.6%. SROC (symmetric receiver operating characteristics) curve represents AUC = 0.99. For grading the accuracy of AI was lower: sensitivity for Gleason grading ranged from 77% to 87%, and specificity from 82% to 90%. CONCLUSIONS: The accuracy of AI for PCa identification and grading is comparable to expert pathologists. This is a promising approach which has several possible clinical applications resulting in expedite and optimize pathology reports. AI introduction into common practice may be limited by difficult and time-consuming convolutional neural network training and tuning.
引用
- Morozov A, Taratkin M, Bazarkin A, et al. A systematic review and meta-analysis of artificial intelligence diagnostic accuracy in prostate cancer histology identification and grading. Prostate Cancer Prostatic Dis. 2023. PMID: 37185992. doi:10.1038/s41391-023-00673-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。