文献速递男科与性医学

双侧海绵体动脉结扎治疗充气式阴茎假体植入后缺血性阴茎异常勃起

Bilateral Cavernosal Artery Ligation to Treat Ischemic Priapism Following Inflatable Penile Prosthesis Implantation.
PubMed 文献 · Urology · 2023-02-01

本文报告首例已知的充气式阴茎假体植入后复发性急性缺血性阴茎异常勃起的60岁男性病例。患者经超声确诊后,超声引导下苯肾上腺素注射治疗失败,遂行会阴探查及双侧海绵体动脉缝扎结扎,勃起立即缓解,假体重新植入后恢复顺利。作者认为该病例挑战了阴茎异常勃起为二元事件的教条,提示可能因血管钙化导致海绵体动脉流入无对抗及假体存在导致静脉流出受损之间的失衡。

要点

  • 充气式阴茎假体植入后仍可能发生急性缺血性阴茎异常勃起,需警惕此罕见现象。
  • 超声引导下苯肾上腺素注射治疗失败后,双侧海绵体动脉结扎可立即缓解勃起。
  • 作者认为阴茎异常勃起并非二元事件,而是动脉流入与静脉流出之间的失衡。

核心结论

  • 作者报告首例已知的充气式阴茎假体植入后缺血性阴茎异常勃起病例。
  • 作者认为该病例挑战了阴茎异常勃起为二元事件的教条,支持海绵体动脉流入无对抗(可能因血管钙化)与假体导致静脉流出受损之间的失衡。
  • 作者建议假体泌尿外科医生应知晓这一罕见现象,并在个体化基础上考虑所有可用方法。

研究设计与样本

  • 个案报告:一名60岁男性,有复发性缺血性阴茎异常勃起病史但无血红蛋白病,因难治性勃起功能障碍接受充气式阴茎假体植入,手术顺利。

主要发现

  • 术后早期经超声确诊为急性缺血性阴茎异常勃起。
  • 因疼痛尝试超声引导下苯肾上腺素注射治疗,但未成功。
  • 探查确认远端缺血性阴茎异常勃起,装置外置后近端海绵体流出鲜红色血液。
  • 行会阴探查并缝扎结扎双侧海绵体动脉,勃起立即缓解。
  • 假体重新植入,患者恢复顺利。

临床怎么用

  • 作者建议假体泌尿外科医生应知晓充气式阴茎假体植入后缺血性阴茎异常勃起这一罕见现象。
  • 作者建议在个体化基础上考虑所有可用方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To describe the first known case of recurrent acute priapism after penile prosthesis implantation. MATERIALS AND METHODS: A 60-year-old gentleman with a history of recurrent ischemic priapism without hemoglobinopathy presented with refractory erectile dysfunction and underwent uncomplicated penile prosthesis placement. His course was complicated by early acute ischemic priapism confirmed via ultrasound. Due to his pain, attempts to relieve the priapism using ultrasound-guided phenylephrine injections were attempted but were unsuccessful. RESULTS: He subsequently underwent exploration with confirmation of distal ischemic priapism followed by brisk bright red blood from the proximal corpora upon device externalization. A perineal exploration was performed and the bilateral cavernosal arteries were suture ligated with immediate relief. The device was reimplanted and the patient recovered uneventfully. CONCLUSION: We report the first known case of ischemic priapism following inflatable penile prosthesis implantation. The details of this case challenge the dogma that priapism is a binary event and instead supports an imbalance between unopposed cavernosal artery inflow possibly due to vascular calcifications and compromised venous outflow due to the presence of the device. Prosthetic urologists should be aware of this rare phenomenon and consider all available approaches on an individualized case-by-case basis.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Fascelli M, Lundy SD, Angermeier K, et al. Bilateral Cavernosal Artery Ligation to Treat Ischemic Priapism Following Inflatable Penile Prosthesis Implantation. Urology. 2023. PMID: 36736911. doi:10.1016/j.urology.2022.12.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。