靶心技术优化S3骶孔入路:将可信赖的腔内泌尿外科技术应用于盆腔医学
本文介绍一种靶心技术用于骶神经调控(SNM)中S3骶孔入路,通过C臂旋转使S3骶孔呈 oval 形并实时透视对齐穿刺针,以快速、可预测地进入S3,可能减少手术时间和经皮神经评估(PNE)穿刺次数,并可快速融入现有实践。
要点
- 靶心技术通过C臂从0度旋转至30度使S3骶孔由椭圆形变为卵圆形,便于穿刺对齐。
- 该技术可能缩短手术时间并减少PNE中的穿刺次数。
- 该技术可快速融入现有SNM实践。
核心结论
- 靶心技术可辅助术者在SNM中获得最佳S3骶孔入路,并可快速融入当前实践。
研究设计与样本
- 视频演示技术,描述靶心技术用于SNM中S3骶孔入路的方法。
主要发现
- 靶心技术允许快速且可预测地进入S3。
- 该技术可能减少手术时间、减少PNE中的穿刺次数,并使术者在保持正确内侧方向的同时进入S3。
临床怎么用
- 患者取俯卧位,在正位透视下标记双侧S3骶孔内侧缘及S3水平横线。
- C臂从0度旋转至30度使S3骶孔由椭圆形变为卵圆形。
- 术者用Kelly钳夹持穿刺针,置于皮肤水平、横线头侧约2 cm处,实时透视下使针与影像增强器对齐形成靶心,确定正确角度后进针,对侧骶孔重复操作。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Sacral neuromodulation (SNM) is an advanced therapy that stimulates sacral spinal nerves to modulate bladder or bowel dysfunction and is approved for the treatment of overactive bladder, fecal incontinence, and non-obstructive urinary retention. Prior to implantation, a successful trial period must be performed via percutaneous nerve evaluation (PNE) or a staged trial to assess treatment efficacy. Ideal lead placement in the S3 foramen is imperative to produce an adequate response and successful outcome. Traditional lead placement with fluoroscopic guidance utilizes the anteroposterior (AP) and lateral views. In this abstract we describe an additional modification which may aid lead placement. OBJECTIVE: This video demonstrates the bullseye technique to obtain S3 foramen access for optimal lead placement in SNM. METHODS/MATERIAL: Begin the procedure by placing the patient in the prone position. The medial edges of the S3 foramen are marked bilaterally in the AP view followed by a horizontal marking at the level of S3. The pelvis is imaged with live fluoroscopy starting at 0 degrees and then rotating the C-arm to 30 degrees. This rotation allows the "opening up" of the S3 foramen from an ellipsoid to an oval. The surgeon grasps the needle with a Kelly clamp, placing it at the level of the skin approximately 2 cm cephalad from the horizontal marking. Live fluoroscopy is performed to align the needle with the image intensifier to form the bullseye. Once the correct angle is identified, the needle is advanced. The procedure is repeated on the contralateral foramen. RESULTS: The bullseye technique allows quick and predictable access into S3. It can potentially decrease operating time, minimize needle entries in PNE, and allows the surgeon to access S3 while maintaining proper medial orientation. CONCLUSION: The bullseye technique can assist surgeons in obtaining optimal access in SNM and can quickly be integrated into current practices.
引用
- Liem SS, Demus T, Jivanji D, et al. Bullseye Technique to Optimize S3 Foramen Access: Applying a Trusted Endourology Technique to Pelvic Medicine. Urology. 2022. PMID: 36334773. doi:10.1016/j.urology.2022.10.011