文献速递前列腺癌

共聚焦激光显微镜用于根治性前列腺切除术中手术切缘评估

Confocal laser microscopy for assessment of surgical margins during radical prostatectomy.
PubMed 文献 · BJU Int · 2022-12-18

本研究在50例机器人辅助根治性前列腺切除术中评估共聚焦激光显微镜(CLM)术中切缘评估的可行性,并与神经血管结构邻近冰冻切片检查(NeuroSAFE)对比。共评估96个后外侧切面,CLM识别15个(16%)阳性切缘,NeuroSAFE识别14个(15%),两者一致性κ=0.80;CLM中位操作时间8分钟,显著短于NeuroSAFE的50分钟(P<0.001)。

要点

  • CLM检测阳性切缘的敏感度86%、特异度96%、阳性预测值80%、阴性预测值98%。
  • CLM与NeuroSAFE对阳性切缘的检测一致性κ=0.80。
  • CLM中位操作时间8分钟,显著短于NeuroSAFE的50分钟(P<0.001)。

核心结论

  • 与NeuroSAFE相比,CLM是术中切缘评估的有前景技术,能够缩短术中切缘评估时间。

研究设计与样本

  • 在50例计划行NeuroSAFE的机器人辅助根治性前列腺切除术中评估手术切缘,切取后外侧切面行CLM成像并按NeuroSAFE方案进一步处理,NeuroSAFE发现阳性切缘时行二次切除,随后非盲法评估CLM图像,以常规组织病理学为参照比较两种方法的准确性。

主要发现

  • 共评估96个根治性前列腺切除标本后外侧切面的阳性切缘,CLM识别15个(16%),NeuroSAFE识别14个(15%)。
  • 以最终病理为参照,CLM检测阳性切缘的敏感度86%、特异度96%、阳性预测值80%、阴性预测值98%。
  • 二次切除后13例中6例(46%)发现残留肿瘤,两种技术均识别出这6例。
  • CLM与NeuroSAFE检测阳性切缘的一致性κ=0.80。
  • CLM中位操作时间显著短于NeuroSAFE(8 vs 50分钟,P<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 本研究的主要局限性是CLM图像采用非盲法评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the feasibility of confocal laser microscopy (CLM) for intraoperative margin assessment as faster alternative to neurovascular structure-adjacent frozen-section examination (NeuroSAFE) during robot-assisted radical prostatectomy (RARP). PATIENTS AND METHODS: Surgical margins were assessed during 50 RARP procedures in patients scheduled for NeuroSAFE. Posterolateral sections were cut and imaged with CLM and further processed to conform with the NeuroSAFE protocol. Secondary resection (SR) was performed in case a positive surgical margin (PSM) was observed with NeuroSAFE. Afterwards, the CLM images were non-blinded assessed for the presence of PSMs. The accuracy of both NeuroSAFE and CLM was compared with conventional histopathology. Agreement for detection of PSMs between NeuroSAFE and CLM was evaluated with Cohen's kappa coefficient. Procedure times were compared with a Wilcoxon signed-ranks test. RESULTS: In total, 96 posterolateral sections of RP specimens were evaluated for the presence of PSMs. CLM identified 15 (16%) PSMs and NeuroSAFE identified 14 (15%) PSMs. CLM had a calculated sensitivity, specificity, positive predictive value and negative predictive value of 86%, 96%, 80% and 98% respectively for the detection of PSMs compared to definite pathology. After SR, residual tumour was found in six of 13 cases (46%), which were all identified by both techniques. There was a substantial level of agreement between CLM and NeuroSAFE (κ = 0.80). The median procedure time for CLM was significantly shorter compared to NeuroSAFE (8 vs 50 min, P < 0.001). The main limitation of this study was the non-blinded assessment of the CLM images. CONCLUSIONS: Compared to NeuroSAFE, CLM is a promising technique for intraoperative margin assessment and is able to reduce the time of intraoperative margin assessment.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Baas DJH, Vreuls W, Sedelaar JPM, et al. Confocal laser microscopy for assessment of surgical margins during radical prostatectomy. BJU Int. 2022. PMID: 36440864. doi:10.1111/bju.15938

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。