文献速递前列腺癌

根治性前列腺切除术后复杂Foley导尿管置入

Complex Foley Catheter Placement After Radical Prostatectomy.
PubMed 文献 · Urology · 2022-11-17

本文描述一例53岁男性行机器人辅助腹腔镜根治性前列腺切除术后,尿道Foley导尿管三次脱落或创伤性拔除导致后壁吻合口断裂,采用超声及膀胱镜引导下经腹部途径将导尿管置入膀胱并以单个G管安全Pexy T fastener经腹固定。作者认为在常规固定装置和患者教育不足以防止拔除的罕见严重情况下,经腹部置入并固定导尿管是安全的。

要点

  • 机器人辅助腹腔镜根治性前列腺切除术后早期创伤性导尿管丢失属泌尿外科急症。
  • 导尿管脱落可导致膀胱尿道吻合口尿漏、肠梗阻、感染或脓肿及未来吻合口狭窄。
  • 常规固定装置和患者教育不足时,可经腹部置入并固定导尿管。

核心结论

  • 在机器人辅助腹腔镜根治性前列腺切除术后导尿管反复丢失或创伤性拔除导致后壁吻合口断裂的罕见严重情况下,经腹部可安全置入并固定导尿管。

研究设计与样本

  • 病例报告:一例53岁男性,Grade Group 4(Gleason 4+4)前列腺癌,行机器人辅助腹腔镜根治性前列腺切除术后尿道Foley导尿管脱落或创伤性拔除三次,导致后壁吻合口断裂。

主要发现

  • 采用超声及膀胱镜引导下经腹部途径将导尿管置入膀胱,并以单个G管安全Pexy T fastener经腹固定。

临床怎么用

  • 作者认为,在常规导尿管固定装置和患者教育不足以防止拔除的罕见但严重情况下,可经腹部安全置入并固定导尿管。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To describe a method for replacement of a dislodged critical urethral foley catheter following a robotic- assisted laparoscopic radical prostatectomy. BACKGROUND: Following robotic-assisted laparoscopic radical prostatectomy (RALP), a bladder drainage via catheter is necessary to allow for proper healing of the urethrovesical anastomosis. In most cases, this is done using a transurethral foley catheter.1,2 Early traumatic loss of the urethral catheter following RALP is consider a urologic emergency and can lead to vesicourethral anastomotic urine leak, ileus, infection or abscess, and future anastomotic stenosis.3 Replacing the urethral catheter in this situation can be difficult even in experienced hands and often requires imaging assistance. METHOD: A 53-year-old male with Grade Group 4 (Gleason 4 + 4) prostate cancer underwent an uncomplicated RALP. During his post-operative course, his urethral foley catheter fell out or was traumatically removed three times resulting in disruption of the posterior anastomosis. To replace the urethral catheter and prevent it from being dislodged again, a transabdominal approach under ultrasound and cystoscopic guidance was employed to replace the catheter into the bladder and secure it trans abdominally using a single G-tube safety Pexy T fastener. CONCLUSION: This case reports describes a technique used to replace and secure a urethral foley catheter in a patient who suffered from a posterior anastomotic disruption following repeated loss and traumatic removal of his urethral foley catheter during his RALP post-operative course. While replacement of a dislodged urethral foley catheter following a RALP can be challenging, the catheter can safely be placed and secured trans abdominally in these rare but serious situations where the conventional catheter secure devices and patient education alone are not sufficient to prevent removal.

来源:Urology,查看原文。版权归原作者所有。