球部尿道人工尿道括约肌袖套置入后间歇导尿的指征与结局
该回顾性研究评估了前列腺癌治疗后因压力性尿失禁行球部尿道人工尿道括约肌(AUS)置入且曾行间歇导尿(CIC)的57例患者,比较术后继续或停止CIC者的结局。结果显示两组在袖套侵蚀率(17.9% vs 22.2%,P=.79)及AUS取出或更换率(56.4% vs 44.4%,P=.41)上无显著差异,两组尿失禁均改善。作者认为对不适合确定性梗阻治疗的患者可考虑在持续CIC背景下置入球部AUS。
要点
- 球部AUS置入后继续CIC者袖套侵蚀率为17.9%,停止CIC者为22.2%,两组无显著差异(P=.79)。
- 继续CIC者AUS取出或更换率为56.4%,停止CIC者为44.4%,两组无显著差异(P=.41)。
- 两组患者AUS置入后尿失禁均改善;对不适合梗阻确定性手术者,作者认为可考虑持续CIC下置入球部AUS。
核心结论
- 对不适合 outlet 梗阻确定性治疗的患者,作者认为可考虑在持续间歇导尿背景下置入球部尿道人工尿道括约肌。
研究设计与样本
- 回顾性综述了本机构所有球部尿道人工尿道括约肌手术,纳入有前列腺癌治疗史、因压力性尿失禁置入AUS且有AUS置入前后CIC史的患者,共57例,由两名外科医生诊治。
主要发现
- 57例中18例在AUS置入后继续或首次开始CIC,39例在AUS置入前已停止CIC。
- 继续或停止CIC两组袖套侵蚀率分别为17.9%与22.2%,差异无统计学意义(P=.79)。
- 两组未来AUS取出或更换率分别为56.4%与44.4%,差异无统计学意义(P=.41)。
- 两组患者在AUS置入后尿失禁均改善。
临床怎么用
- 原文结论指出,对不适合 outlet 梗阻确定性治疗的患者,可考虑在持续间歇导尿背景下置入球部尿道人工尿道括约肌。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the functional and surgical impact of CIC protocols in men with a bulbar AUS in place. Stress urinary incontinence (SUI) and poor bladder emptying are both sequelae of prostate cancer treatment, though there is sparse data to guide concomitant management. The safety of intermittent catheterization (CIC) in men with an artificial urinary sphincter (AUS) at the bulbar urethra remains unclear. METHODS: We performed a retrospective review of all bulbar urethral AUS procedures at our institution. Inclusion criteria were patients with a history of prostate cancer treatment, AUS placement for SUI, and a history of CIC before and/or after AUS placement. All eligible cases were retrospectively reviewed. Surgical and continence outcomes were analyzed. RESULTS: A total of 57 patients were identified with a history of CIC and AUS placement under the care of two surgeons. Eighteen continued to perform CIC or first initiated CIC after AUS placement and 39 discontinued CIC prior to AUS placement. The incidence of erosion was no different amongst patients who continued or discontinued CIC after AUS placement (17.9% vs 22.2%, P = .79). There was no difference in future AUS removal or replacement (56.4% vs 44.4%, P = .41). Both groups experienced improvement in urinary incontinence after placement of an AUS. CONCLUSION: Bulbar AUS placement in the setting of continuous intermittent catheterization can be considered in patients who are not surgical candidates for definitive treatment of their outlet obstruction.
引用
- Krughoff K, Livingston AJ, Inouye B, et al. Indications and Outcomes for Intermittent Catheterization following Bulbar AUS Cuff Placement. Urology. 2022. PMID: 36332702. doi:10.1016/j.urology.2022.10.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。