文献速递男科与性医学

动态超声中能量多普勒前瞻性横断面评估静脉闭塞性勃起功能障碍的阴茎螺旋动脉循环

Prospective Cross-Sectional Evaluation of Penile Helicine Circulation by Power Doppler During Dynamic Ultrasound in Veno-Occlusive Erectile Dysfunction.
PubMed 文献 · Urology · 2022-08-18

前瞻性横断面研究纳入202例勃起功能障碍患者(平均IIEF-5为13.5),在海绵体内注射血管活性药物后行动态能量多普勒,应答不佳者再行海绵体测压。能量多普勒诊断静脉闭塞性功能障碍的敏感度为52.4%,特异度为78.8%,总诊断准确率为73.3%;海绵体终末单元形态异常者发生静脉闭塞性功能障碍的风险约为正常者的4倍(OR=4.076)。

要点

  • 能量多普勒诊断静脉闭塞性功能障碍敏感度52.4%、特异度78.8%。
  • 海绵体终末单元形态异常者静脉闭塞性功能障碍风险约为正常者4倍(OR=4.076)。
  • 96例注射试验应答不佳者行海绵体测压,其中42例(43.7%)阳性。

核心结论

  • 海绵体终末单元形态异常的患者发生静脉闭塞性功能障碍的风险约为能量多普勒表现正常者的4倍(OR=4.076;95%CI:1.996-8.327)。

研究设计与样本

  • 前瞻性横断面研究,纳入勃起功能障碍至少6个月、平均IIEF-5为13.5(12-17)的患者。
  • 所有患者在海绵体内注射血管活性药物(前列腺素E1 20 mcg和罂粟碱6 mg)后行动态能量多普勒,应答不佳者再行海绵体测压。
  • 共纳入202例患者,平均年龄46岁。

主要发现

  • 96例(47.5%)对海绵体内注射试验应答不佳者行海绵体测压,其中42例(43.7%)静脉闭塞性功能障碍阳性。
  • 在160例无静脉闭塞性功能障碍的患者(54例海绵体测压阴性+106例注射试验应答者)中,能量多普勒显示海绵体终末单元「低流量」血管形态正常者126例(78.8%),异常者34例(21.3%)。
  • 能量多普勒诊断静脉闭塞性功能障碍的敏感度为52.4%(阳性预测值39.3%),特异度为78.8%(阴性预测值86.3%),总诊断准确率为73.3%。

关键数值与推荐

  • 能量多普勒诊断静脉闭塞性功能障碍的敏感度为52.4%,阳性预测值为39.3%。
  • 能量多普勒诊断静脉闭塞性功能障碍的特异度为78.8%,阴性预测值为86.3%。
  • 能量多普勒的总诊断准确率为73.3%。
  • 海绵体终末单元形态异常者静脉闭塞性功能障碍的OR=4.076(95%CI:1.996-8.327)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the usefulness of Power Doppler to improve the diagnostic work up of veno-occlusive erectile dysfunction patients. MATERIALS AND METHODS: Patients affected by erectile dysfunction, mean IIEF 5 = 13.5 (12-17) for at least 6 months, were enrolled in a prospective cross-sectional study. All patients underwent Dynamic Power Doppler after intracavernous injection of vasoactive drugs (PGE1 20 mcg and Papaverine 6 mg). Poor responders' patients subsequently underwent to cavernosometry to get a full assessment of the vascular framework. RESULTS: 202 patients (mean age 46 years), were included in the study. 96 subjects (47.5%) who did not adequately respond to the intracavernous injection -test, subsequently underwent to cavernosometry. In 42 of 96 patients (43.7%) cavernosometry was positive for veno-occlusive dysfunction. In a total of 160 patients who did not have veno-occlusive dysfunction (54 with negative cavernosometry + 106 intracavernous injection-test responders), the Power Doppler was normal in 126 (78.8%) and pathological in 34 (21.3%) in terms of steric conformation of "low flow" vessels corresponding to the Cavernosal Terminal Unit. The diagnostic sensitivity of Power Doppler towards veno-occlusive dysfunction was found to be 52.4% (Positive Predictive Value: 39.3%), the specificity was 78.8% (Negative Predictive Value: 86.3%) and the total diagnostic accuracy was equal to 73.3%. CONCLUSION: Collected data evidenced that patients who reported altered morphological features of the Cavernosal Terminal Unit had an approximately 4-fold greater risk of having veno-occlusive dysfunction compared to patients who had normal Power Doppler features (OR = 4.076; 95% CI: 1.996-8.327).

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Zucchi A, Pezzoni F, Pastore AL, et al. Prospective Cross-Sectional Evaluation of Penile Helicine Circulation by Power Doppler During Dynamic Ultrasound in Veno-Occlusive Erectile Dysfunction. Urology. 2022. PMID: 35988732. doi:10.1016/j.urology.2022.08.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。