文献速递前列腺增生与排尿功能障碍男科与性医学

人工尿道括约肌压力调节球囊腹部与腹股沟下放置的比较

Abdominal vs Sub-Inguinal Placement of Pressure Regulating Balloon for Artificial Urinary Sphincter.
PubMed 文献 · Urology · 2022-08-02

回顾性分析2010至2020年单术者182例人工尿道括约肌植入,比较压力调节球囊经腹股沟下与腹部放置的围手术期及术后结局。腹股沟下入路92%成功完成,手术时间三组无显著差异,但腹股沟下或转开腹组出现5例泵向上移位;作者认为该入路安全但泵移位风险增加,后者可能与所有腹股沟下病例均采用肉膜下囊袋放置泵有关。

要点

  • 腹股沟下入路压力调节球囊放置成功率92%,转腹部放置率8.3%。
  • 三组手术时间中位数62、75、77分钟,差异无统计学意义(P=0.30)。
  • 泵向上移位5例均见于腹股沟下或转开腹组(P=0.05),作者认为可能与肉膜下囊袋放置泵有关。

核心结论

  • 腹股沟下入路放置压力调节球囊安全且成功率超过90%,但不比腹部入路更快,且与泵移位风险增加相关,后者可能受所有腹股沟下病例均采用肉膜下囊袋放置泵的混杂影响。

研究设计与样本

  • 回顾性综述,纳入2010至2020年单术者所有人工尿道括约肌植入共182例,按压力调节球囊放置技术分为腹股沟下组、腹部组和术中由腹股沟下转开腹组(转换组)。

主要发现

  • 腹股沟下入路在144例中成功完成132例(92%),144例中12例(8.3%)转为腹部放置。
  • 既往腹腔镜辅助机器人前列腺癌根治术或放疗未增加转换风险。
  • 手术时间中位数腹股沟下组62分钟、腹部组75分钟、转换组77分钟(P=0.30)。
  • 装置激活时间中位数腹部组25.0天、腹股沟下组32.0天、转换组37.5天(P<0.01)。
  • 各组均无肠管或膀胱损伤及压力调节球囊疝出,但泵向上移位5例均见于腹股沟下组或转换组(P=0.05)。

临床怎么用

  • 作者认为腹股沟下入路放置压力调节球囊安全且成功率超过90%,但不比腹部入路更快,且与泵移位风险增加相关,后者可能受所有腹股沟下病例均采用肉膜下囊袋放置泵的混杂影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To compare peri- and postoperative outcomes following artificial urinary sphincter (AUS) insertion using an abdominal versus a sub-inguinal counterincision for pressure regulating balloon (PRB) placement. METHODS: This was a retrospective review of all AUS placements by a single surgeon from 2010-2020. Demographic, clinical, and surgical details were obtained from chart review. The cohorts were divided by PRB placement technique (sub-inguinal, abdominal, and attempted sub-inguinal converted intra-operatively to abdominal ["conversion group"]). RESULTS: There were 182 AUS devices placed. The sub-inguinal approach was successfully completed in 132/144 (92%) and converted to abdominal PRB placement in 12/144 (8.3%). The risk of conversion was not increased by prior laparoscopically-assisted robotic prostatectomy (LRP) or radiotherapy (RT). Median operative time was 62, 75, and 77 minutes for sub-inguinal, abdominal, and conversion groups, respectively ( P = 0.30). Time to device activation was 25.0, 32.0, and 37.5 days for abdominal, sub-inguinal, and conversion groups, respectively (P<0.01). There were no bowel or bladder injuries and no PRB herniation in any group; however, there were five instances of pump migration superiorly, all in the sub-inguinal or conversion groups (P = 0.05). CONCLUSIONS: The sub-inguinal approach to PRB placement during AUS is safe and can be successfully completed over 90% of the time. However, it is not faster than the abdominal approach to PRB placement and it is associated with an increased risk of pump migration, though the latter may be confounded by the sub-dartos pouch for pump placement that was used in all sub-inguinal cases.

来源:Urology,查看原文。版权归原作者所有。

引用

  1. Lauwagie A, Kasabwala K, Grove S, et al. Abdominal vs Sub-Inguinal Placement of Pressure Regulating Balloon for Artificial Urinary Sphincter. Urology. 2022. PMID: 35931240. doi:10.1016/j.urology.2022.07.034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。