活体猪模型中输尿管软镜术中液体吸收的评价
本研究在活体猪模型中评估输尿管软镜(fURS)术中肾盂压力与液体吸收的关系。18只猪肾在37、55、75和150 mmHg肾盂压力下模拟fURS 1小时,结果显示肾盂压力升高与冲洗液吸收量和吸收速率增加相关。
要点
- 模拟fURS 1小时后,肾盂压力37、55、75和150 mmHg时平均吸收量分别为7.6、10.8、26.0和56.8 mL
- 与37 mmHg相比,75和150 mmHg时液体吸收量显著增加(P=0.026和P=0.047)
- 与37 mmHg相比,75和150 mmHg时吸收速率显著增加(均P<0.001)
核心结论
- 在活体猪fURS模型中,肾盂压力升高与冲洗液吸收量及吸收速率增加相关。
研究设计与样本
- 活体猪模型研究,对18只麻醉雌性约克夏猪的18个猪肾行输尿管软镜(fURS)模拟手术。
主要发现
- 模拟fURS 1小时后,肾盂压力37、55、75和150 mmHg时平均(SD)冲洗液吸收量分别为7.6(5.7)、10.8(7.1)、26.0(15.8)和56.8(22.3)mL。
- 与肾盂压力37 mmHg相比,75和150 mmHg时液体吸收量显著增加(P=0.026和P=0.047)。
- 与肾盂压力37 mmHg相比,75和150 mmHg时吸收速率显著增加(均P<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the relationship between renal pelvis pressure and fluid absorption during ureteroscopy (URS) in a live porcine model. MATERIALS AND METHODS: Flexible URS (fURS) was performed in anaesthetised female Yorkshire pigs. Prior to performing fURS, a 0.3556-mm (0.014″) pressure-sensing guidewire (Comet™, Boston Scientific) was placed to monitor renal pelvis pressure. A simulated fURS procedure was then performed for 1 h. Infusion of irrigation fluid (5% ethanol in saline) at target renal pelvis pressures (37-150 mmHg) was maintained for 1 h using a pressure bag and real-time feedback from the pressure-sensing guidewire. Venous blood was sampled every 10 min. The volume of irrigation fluid absorbed was estimated with established equations. RESULTS: A URS procedure was performed in vivo in 18 porcine kidneys and the volume of irrigation fluid absorbed during the 1 h URS was calculated. The mean (SD) volume of irrigation fluid absorbed after 1 h of simulated URS was 7.6 (5.7), 10.8 (7.1), 26.0 (15.8), and 56.8 (22.3) mL at renal pelvis pressures of 37, 55, 75, and 150 mmHg, respectively. Compared with URS with renal pelvis pressure of 37 mmHg, the volume of fluid absorption was significantly greater at renal pelvis pressures of 75 and 150 mmHg (P = 0.026 and P = 0.047, respectively). In addition, compared with URS with renal pelvis pressure of 37 mmHg, the rate of absorption was significantly greater at renal pelvis pressures of 75 and 150 mmHg (both P < 0.001). CONCLUSION: In this study of an in vivo porcine model of URS, increasing renal pelvis pressures during URS were associated with increases in irrigation fluid absorption and increases in the rate of fluid absorption.
引用
- Kottooran C, Twum-Ampofo J, Lee J, et al. Evaluation of fluid absorption during flexible ureteroscopy in an in vivo porcine model. BJU Int. 2022. PMID: 35861056. doi:10.1111/bju.15858
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。