儿科输尿管镜手术中超脉冲铥光纤激光与低功率钬激光的治疗结果比较
本研究为回顾性连续队列研究,纳入2016至2021年接受单侧输尿管镜激光碎石术的儿科患者,比较超脉冲铥光纤激光(SPTF)与低功率钬激光(Ho:YAG)的疗效。结果显示SPTF组无石率70% vs Ho:YAG组59%,SPTF组残留结石碎片的比值显著更低(OR=0.39,95%CI:0.19-0.77,p=0.01),手术时间与并发症无显著差异。
要点
- SPTF组无石率70%,Ho:YAG组59%,SPTF组残留碎片风险显著更低(OR=0.39)。
- 手术时间两组无显著差异(p=0.8)。
- 并发症SPTF组7例(25%),Ho:YAG组19例(22%),无显著差异(p=0.6)。
核心结论
- SPTF激光与低功率Ho:YAG激光相比无石率更高,且不损害手术时间与安全性。
研究设计与样本
- 回顾性连续队列研究,纳入2016至2021年接受单侧输尿管镜激光碎石术的儿科患者。
- 共125例手术,来自109例儿科患者:Ho:YAG组93例,SPTF组32例。
- 采用倾向性评分校正队列不平衡,用逻辑回归分析30天并发症与无石状态,用线性回归比较手术时间。
主要发现
- 总体无石率为62%;SPTF组70%,Ho:YAG组59%。
- SPTF组残留结石碎片的比值显著低于Ho:YAG组(OR=0.39,95%CI:0.19-0.77,p=0.01)。
- 手术时间两组无显著差异(p=0.8)。
- 并发症SPTF组7例(25%),Ho:YAG组19例(22%),无显著差异(p=0.6)。
- 年龄(p=0.2)、性别(p=0.6)、结石负荷(p>0.9)和结石位置(p=0.1)两组无显著差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The thulium fiber laser is a promising new lithoptripsy technology never before studied in the pediatric population. Our center adopted the first platform in North America, the SuperPulsed thulium fiber laser (SPTF). We aimed to compare outcomes in pediatric ureteroscopy using the SPTF to those using the gold standard, low-power holmium:yttrium-aluminum-garnet (Ho:YAG) laser. MATERIALS AND METHODS: This is a retrospective, consecutive cohort study of unilateral ureteroscopy with laser lithotripsy performed in pediatric patients from 2016 to 2021 as an early adopter of the SPTF. Thirty-day complications and stone-free status, defined as the absence of a stone fragment on followup imaging within 90 days, were analyzed using logistic regression. Operative times were compared using linear regression. Propensity scores for use of SPTF were used in regression analyses to account for potential cohort imbalance. RESULTS: A total of 125 cases were performed in 109 pediatric patients: 93 with Ho:YAG and 32 with SPTF. No significant difference was noted in age (p=0.2), gender (p=0.6), stone burden (p >0.9) or stone location (p=0.1). The overall stone-free rate was 62%; 70% with SPTF and 59% with Ho:YAG. The odds of having a residual stone fragment were significantly lower with SPTF than with Ho:YAG (OR=0.39, 95% CI: 0.19-0.77, p=0.01). There was no significant difference in operative time (p=0.8). Seven (25%) complications were noted with SPTF and 19 (22%) with Ho:YAG (p=0.6). CONCLUSIONS: The SPTF laser was associated with a higher stone-free rate than the low-power Ho:YAG laser without compromising operative time and safety.
引用
- Jaeger CD, Nelson CP, Cilento BG, et al. Comparing Pediatric Ureteroscopy Outcomes with SuperPulsed Thulium Fiber Laser and Low-Power Holmium:YAG Laser. J Urol. 2022. PMID: 35703000. doi:10.1097/JU.0000000000002666
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。