膀胱超声预测内镜下输尿管膀胱壁内段透明质酸/葡聚糖微球(Deflux)注射后膀胱输尿管反流缓解的疗效
2014至2020年160例(220条输尿管)原发性膀胱输尿管反流患儿接受输尿管膀胱壁内段Deflux注射,低级别反流190条、高级别30条,术后3个月和12个月行膀胱超声和排尿性膀胱尿道造影随访。单次注射后低级别反流影像学成功率为98%、高级别为26.7%,膀胱超声检出Deflux植入物的比例分别为89%和43.3%。作者认为膀胱超声对低级别反流随访可调整、高级别反流保留排尿性膀胱尿道造影。
要点
- 单次Deflux注射后低级别反流影像学成功率为98%,高级别为26.7%。
- 末次随访膀胱超声检出Deflux植入物低级别89%、高级别43.3%。
- 低级别反流中膀胱超声检测Deflux的敏感性、阳性预测值和准确率高于高级别。
核心结论
- 膀胱超声检测Deflux植入物高度敏感。
- 作者认为低级别反流经Deflux注射治疗后的随访可调整膀胱超声,高级别反流随访保留排尿性膀胱尿道造影,以减少低级别反流患儿排尿性膀胱尿道造影的不必要辐射暴露。
研究设计与样本
- 2014年至2020年纳入160例(220条输尿管)接受输尿管膀胱壁内段Deflux注射治疗原发性膀胱输尿管反流的儿童。
- 手术时平均年龄72个月,低级别反流(II-III级)190条输尿管,高级别反流(IV-V级)30条输尿管,60例患者行双侧手术。
- 所有患者在3个月和12个月时行膀胱超声和排尿性膀胱尿道造影随访。
主要发现
- 单次Deflux注射末次随访影像学成功率低级别反流患者为98%,高级别反流患者为26.7%。
- 末次随访膀胱超声检出Deflux植入物低级别反流患者为89%,高级别反流患者为43.3%。
- 低级别反流患者较高级别反流患者,膀胱超声检测Deflux的敏感性、阳性预测值和准确率更高。
临床怎么用
- 作者认为低级别反流经Deflux注射治疗后的随访可调整膀胱超声。
- 作者认为高级别反流随访可保留排尿性膀胱尿道造影。
- 作者认为上述做法可减少低级别反流患儿排尿性膀胱尿道造影的不必要辐射暴露。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the efficacy of bladder ultrasound (US) in predicting the resolution of vesicoureteral reflux (VUR) after subureteral endoscopic Deflux injection in low-grade vs high-grade VUR patients. MATERIALS AND METHODS: Between 2014 and 2020, 160 children (220 ureters) were administered subureteral Deflux injection for treatment of primary VUR. The mean age at surgery was 72 months. Low-grade reflux (grades II-III) was observed in 190 ureters and high-grade reflux (grades IV-V) was observed in 30 ureters. Bilateral surgery was performed in 60 patients. All patients had follow-up using bladder US and voiding cystourethrography (VCUG) at 3 months and 12 months. Outcome included identification of Deflux mounds by bladder US and correlation of Deflux mounds identified with radiographic success rates of VUR on VCUG. RESULTS: Single Deflux injection showed radiographic success rates in 98% of low grade reflux patients and 26.7% of high grade reflux patients at last follow-up. Bladder US was able to detect Deflux mounds in 89% of low grade reflux and 43.3% of high grade reflux patients at last follow up. Our study demonstrated higher sensitivity, Positive predictive value and accuracy in Deflux detection by bladder US in low grade reflux vs high grade reflux patients. CONCLUSION: Bladder-US was highly sensitive for detection of Deflux implants. Bladder-US could be adjusted in follow-up of patients with low-grade reflux treated by Deflux injection, while VCUG could be preserved for follow-up of high-grade reflux, this will lead to reduction of unnecessary radiation exposure during VCUG for children with low grade reflux.
引用
- Aboutaleb H, Eldib DB, Farahat Y, et al. Efficacy of Bladder Ultrasound in Prediction of Resolution of Vesicoureteral Reflux After Endoscopic Subureteral Hyaluronic Acid/Dextranomer (Deflux) Injection. Urology. 2022. PMID: 35065987. doi:10.1016/j.urology.2022.01.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。