机器学习用于尿动力学检测逼尿肌过度活动
本研究开发机器学习算法,在脊柱裂患者尿动力学检查中识别逼尿肌过度活动。纳入2012年5月至2020年9月单中心小儿泌尿科805份尿动力学文件(546例患者),构建时域与频域模型。三通道时域模型AUC最高为91.9±1.3%,三通道频域模型特异性最高为92.9±1.1%。
要点
- 三通道时域模型AUC 91.9±1.3%,敏感度84.2±3.8%,特异性86.4±1.3%。
- 三通道频域模型AUC 90.5±1.9%,敏感度68.3±5.3%,特异性92.9±1.1%。
- 多通道与数据加窗可提升模型检测逼尿肌过度活动的性能。
核心结论
- 研究开发了有前景的概念验证机器学习流程,可在尿动力学检查中识别逼尿肌过度活动。
- 作者认为基于机器学习的预测建模算法或可用于标准化尿动力学解读,并可能辅助共同决策和改善患者照护。
研究设计与样本
- 研究纳入2012年5月至2020年9月单中心小儿泌尿科接受尿动力学检查的患者。
- 尿动力学文件在时域和频域分析,并变化纳入膀胱压、腹压和逼尿肌压通道。
- 采用数据加窗、降维和支持向量机构建机器学习流程,模型设计用于检测临床医生判定的逼尿肌过度活动。
- 数据提取自546例独特患者的805份尿动力学检查文件。
主要发现
- 所生成模型在检测逼尿肌过度活动与临床医生判定一致性方面,时域和频域方法均取得良好性能指标。
- 纳入多通道和数据加窗改善了模型性能。
- 三通道时域模型AUC最高为91.9±1.3%,敏感度84.2±3.8%,特异性86.4±1.3%。
- 三通道频域模型特异性最高为92.9±1.1%,AUC为90.5±1.9%,敏感度68.3±5.3%。
临床怎么用
- 作者认为机器学习预测建模算法或可用于标准化尿动力学解读,并可能辅助共同决策和改善患者照护。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To develop a machine learning algorithm that identifies detrusor overactivity (DO) in Urodynamic Studies (UDS) in the spina bifida population. UDS plays a key role in assessment of neurogenic bladder in patients with spina bifida. Due to significant variability in individual interpretations of UDS data, there is a need to standardize UDS interpretation. MATERIALS AND METHODS: Patients who underwent UDS at a single pediatric urology clinic between May 2012 and September 2020 were included. UDS files were analyzed in both time and frequency domains, varying inclusion of vesical, abdominal, and detrusor pressure channels. A machine learning pipeline was constructed using data windowing, dimensionality reduction, and support vector machines. Models were designed to detect clinician identified detrusor overactivity. RESULTS: Data were extracted from 805 UDS testing files from 546 unique patients. The generated models achieved good performance metrics in detecting DO agreement with the clinician, in both time- and frequency-based approaches. Incorporation of multiple channels and data windowing improved performance. The time-based model with all 3 channels had the highest area under the curve (AUC) (91.9 ± 1.3%; sensitivity: 84.2 ± 3.8%; specificity: 86.4 ± 1.3%). The 3-channel frequency-based model had the highest specificity (AUC: 90.5 ± 1.9%; sensitivity: 68.3 ± 5.3%; specificity: 92.9 ± 1.1%). CONCLUSION: We developed a promising proof-of-concept machine learning pipeline that identifies DO in UDS. Machine-learning-based predictive modeling algorithms may be employed to standardize UDS interpretation and could potentially augment shared decision-making and improve patient care.
引用
- Hobbs KT, Choe N, Aksenov LI, et al. Machine Learning for Urodynamic Detection of Detrusor Overactivity. Urology. 2021. PMID: 34757048. doi:10.1016/j.urology.2021.09.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。