文献速递针灸推拿中医内科

电针后处理对大鼠缺血再灌注损伤心室单相动作电位及心功能的影响

Effects of post-treatment electroacupuncture on ventricular monophasic action potential and cardiac function in a rat model of ischemia/reperfusion injury.
PubMed 文献 · Acupunct Med · 2021-09-23

研究将雄性SD大鼠随机分为假手术组、缺血再灌注组和缺血再灌注+电针组(每组n=8),电针取PC6穴30分钟。结果显示电针后处理可改善缺血再灌注引起的心率、平均动脉压及心功能指标下降,缩短延长的MAPD50和MAPD90,降低CK-MB和cTnI水平,并减少再灌注心律失常发生率。

要点

  • 电针后处理可改善缺血再灌注大鼠的心功能与心室电生理指标。
  • 电针可缩短延长的MAPD50和MAPD90,降低再灌注心律失常发生率。
  • 电针后处理降低CK-MB和cTnI水平,提示减轻心肌损伤。

核心结论

  • 电针后处理可缓解缺血再灌注期间心室肌复极延长和除极减慢,从而降低再灌注心律失常发生率。

研究设计与样本

  • 雄性SD大鼠随机分为假手术组、缺血再灌注组和缺血再灌注+电针组,每组n=8。
  • 缺血再灌注模型通过结扎左冠状动脉前降支30分钟建立,再灌注30分钟。
  • 电针取PC6穴30分钟,于开放冠状动脉再灌注期间实施。

主要发现

  • 与假手术组相比,缺血再灌注组心率、平均动脉压、Vmax、CV、ERP和MAPA明显降低,MAPD50和MAPD90延长,CK-MB和cTnI升高(p < 0.05)。
  • 与缺血再灌注组相比,电针组心率、平均动脉压、Vmax、CV、ERP和MAPA升高,MAPD50和MAPD90缩短,CK-MB和cTnI降低(p < 0.05)。
  • 三组间VFT差异无统计学意义(p > 0.05)。

关键数值与推荐

  • 缺血再灌注组较假手术组心率、平均动脉压、Vmax、CV、ERP和MAPA降低(p < 0.05)。
  • 缺血再灌注组较假手术组MAPD50和MAPD90延长,CK-MB和cTnI升高(p < 0.05)。
  • 电针组较缺血再灌注组MAPD50和MAPD90缩短,CK-MB和cTnI降低(p < 0.05)。
  • 三组间VFT差异无统计学意义(p > 0.05)。

临床怎么用

  • 动物实验提示电针PC6后处理可能减轻心肌缺血再灌注损伤并降低再灌注心律失常风险。
  • 临床决策需结合人体证据,不能直接外推至患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To determine the effects of post-treatment electroacupuncture (EA) on the electrophysiological properties of ventricular muscle in rats with ischemia/reperfusion (IR) injury. METHODS: Male Sprague-Dawley (SD) rats were randomly assigned into sham-operated (SH), IR and IR + EA groups (n = 8 each). The IR model was generated by ligation of the left anterior descending (LAD) coronary artery for 30 min. After establishing the IR model, EA was administered at PC6 for 30 min while opening the coronary artery and allowing reperfusion for 30 min. Heart rate (HR), mean arterial pressure and monophasic action potential (MAP) of cardiac muscle in the outer membrane of the antetheca of the left ventricle before coronary artery ligation (T0), after coronary artery ligation for 30 min (T1) and after reperfusion for 30 min (T2) were recorded. At the same time, ventricular electrophysiological parameters including ventricular effective refractory period (ERP), conduction velocity (CV) and ventricular fibrillation threshold (VFT) were measured. Then, the cardiac function and the levels of creatine kinase-muscle/brain (CK-MB) and cardiac troponin I (cTnI) were monitored. Based on these data, monophasic action potential amplitude (MAPA), the maximum depolarization velocity (Vmax) and the MAP durations at 50% and 90% repolarization (MAPD50 and MAPD90) were calculated to determine the incidence of arrhythmia during reperfusion. RESULTS: Compared with the SH group, the IR group showed an obviously decreased HR as well as reduced mean arterial pressure, Vmax, CV, ERP and MAPA. All indices of cardiac function except left ventricular end-diastolic pressure (LVEDP) decreased (i.e. ventricular systolic pressure (LVSP), left ventricular ejection fraction (LVEF), fractional shortening (FS) and rate of the ventricular pressure rise/drop (±dp/dt)). Furthermore, the MAPD50 and MAPD90 were prolonged, and the levels of CK-MB and cTnI increased (p < 0.05). In comparison to the IR group, HR and the mean arterial pressure were increased. All indices of cardiac function except LVEDP increased (LVSP, LVEF, FS and ±dp/dt). Vmax, CV, ERP and MAPA were also increased in the IR + EA group. However, MAPD50 and MAPD90 were distinctly shortened, and the levels of CK-MB and cTnI decreased (p < 0.05). There were no statistically significant differences in VFT between the three groups (p > 0.05). CONCLUSION: EA post-treatment can relieve prolongation of repolarization and slowed depolarization of ventricular muscle during IR, thus decreasing the rate of incidence of reperfusion arrhythmia.

来源:Acupunct Med,查看原文。版权归原作者所有。

引用

  1. Tang J, Ren W, Liu Y, et al. Effects of post-treatment electroacupuncture on ventricular monophasic action potential and cardiac function in a rat model of ischemia/reperfusion injury. Acupunct Med. 2021. PMID: 34553613. doi:10.1177/09645284211039229

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。