用于无创艾灸治疗的超声装置研制

Ultrasonic device developed for non-invasive moxibustion therapy.
PubMed 文献 · Integr Med Res · 2021-05-19

本研究设计、模拟、制造并测试了一种超声艾灸装置(UMD),旨在克服传统艾灸的烧伤、烟雾、过敏等不良反应。该装置主要部件为1 MHz凹透镜超声换能器及其 applicator,通过COMSOL有限元法模拟声压与温度分布,并在猪皮和小鼠腹部进行实验验证。结果显示模拟与实验温度分布一致,小鼠腹部组织学图像未见皮肤组织损伤,表明该装置可克服传统艾灸缺点并达到设计参数。

要点

  • 超声艾灸装置(UMD)以1 MHz凹透镜超声换能器为核心部件。
  • 有限元模拟的温度与声压分布和猪皮实验验证结果一致。
  • 小鼠腹部120分钟治疗后组织学图像未见皮肤组织损伤。

核心结论

  • 新开发的UMD可克服传统艾灸疗法的缺点并达到提出的设计参数。

研究设计与样本

  • 研究设计、模拟、制造并测试了超声艾灸装置(UMD),主要部件为1 MHz凹透镜超声换能器及其 applicator。
  • 采用基于有限元法的COMSOL软件模拟换能器的声压与温度分布。
  • 在猪皮上进行温度分布实验验证,并在小鼠腹部皮肤进行120分钟艾灸治疗性能测试并获取组织学图像。

主要发现

  • 有限元模拟的温度分布和声压与实验结果一致。
  • 组织学图像显示小鼠腹部治疗后无皮肤组织损伤。

关键数值与推荐

  • UMD主要部件为1 MHz凹透镜超声换能器及其 applicator。
  • 猪皮温度变化曲线在非聚焦点(2 mm)和焦距13 mm处获取。
  • 小鼠腹部艾灸治疗时间为120分钟。

临床怎么用

  • 该UMD作为无创艾灸装置,未来可与传统艾灸疗法进行性能比较研究。

局限性

  • 研究仅为装置开发与初步性能测试,尚未与传统艾灸疗法进行直接比较。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Recently, some adverse effects of moxibustion has been reported such as burns, smoke, allergies, and so on. To overcome the adverse effects of traditional moxibustion, an ultrasonic moxibustion device (UMD) was designed, simulated, fabricated, and tested. The objective of this study is to provide detailed information about the main design parameters, simulation outcome, and performance-test results. METHODS: The main components of the UMD are a 1-MHz ultrasonic transducer (UT) with concave lens, and its applicator. The acoustic pressure and temperature distribution of the UT was simulated and described graphically using COMSOL software, which is based on the finite element method (FEM). Experimental verification of the temperature distribution was performed on the skin of pork. The temperature-change profiles of pork in relation to increase of therapy time were obtained at an unfocused point (2 mm) and at a focal distance of 13 mm. For the performance test, moxibustion therapy was conducted on the abdominal skin of mice for 120 min using the new UMD and its histological images were acquired to analyze the skin-tissue damage. RESULTS: The FEM simulation of temperature distribution and acoustic pressure agreed with the experimental outcome. Histological images showed that there was no skin-tissue damage to the mouse abdomens after therapy. The results clearly show that the newly developed UMD can overcome the disadvantages of traditional moxibustion therapy and achieve the proposed design parameters. CONCLUSION: The FEM simulation and performance tests provided valuable information about developing future UMDs. In addition, its performance can be compared with traditional moxibustion therapy for future study.