文献速递针灸推拿

BL40穴安全针刺深度与角度的MRI研究

Magnetic resonance imaging study of safe needling depth and angulation for acupuncture at BL40.
PubMed 文献 · Acupunct Med · 2020-10-09

以穿刺点至腘动脉距离(AN)的70%为安全深度,BL40直线与AN线夹角α为安全角度,分析性别与BMI的影响。结果示总体安全深度18.51±3.56 mm,肥胖组22.01±3.71 mm;建议直刺25 mm针约进12.5 mm,BMI>28 kg/m²者可进17.5 mm。

要点

  • BL40直刺安全深度总体约18.5 mm,肥胖者更深。
  • 建议25 mm针直刺约12.5 mm,BMI>28 kg/m²可至17.5 mm。
  • 低体重或矮小患者应减少进针深度。

核心结论

  • BL40直刺时总体安全深度为18.51±3.56 mm,肥胖组为22.01±3.71 mm。
  • 建议25 mm针直刺约进12.5 mm,BMI>28 kg/m²者可进17.5 mm。
  • 低体重或矮小患者应减少进针深度。

研究设计与样本

  • 以穿刺点至腘动脉距离(AN)的70%为安全深度,BL40直线与AN线夹角α为安全角度。

主要发现

  • 总体安全深度18.51±3.56 mm(95%CI 17.88%-19.14%)。
  • 低/正常BMI组安全深度17.24±3.14 mm,超重组18.76±2.90 mm,肥胖组22.01±3.71 mm。
  • 角度α平均内偏8.78°±2.92°(95%CI 7.01°-10.55°),外偏9.75°±3.46°(95%CI 9.10°-10.41°)。

关键数值与推荐

  • 安全深度定义为穿刺点至腘动脉距离(AN)的70%。
  • 安全角度为BL40直线与AN线夹角α。
  • BMI分组:低/正常、超重、肥胖,肥胖组安全深度22.01±3.71 mm。

临床怎么用

  • BL40直刺时参考总体安全深度约18.5 mm,肥胖者可达约22 mm。
  • 使用25 mm针直刺建议进约12.5 mm,BMI>28 kg/m²者可进17.5 mm。
  • 低体重或矮小患者应适当减少进针深度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The objectives of this study were to identify the mean safe needling depth and angle at BL40 between subjects, taking into account variables including sex and body mass index (BMI). METHODS: One hundred and twenty-four participants who had undergone magnetic resonance imaging (MRI) examination of the knee region for clinical indications were included in this study. BL40 needling sites were localized by World Health Organization (WHO) standards and were measured by MRI. As much as 70% of the value of AN (from the needle insertion point to the popliteal artery) was considered to represent the safe depth, and angle alpha between the BL40 straight line and the AN line was regarded as the safe angle. RESULTS: Overall, mean safe depth regardless of BMI and sex was 18.51 ± 3.56 mm (95% confidence interval (CI), 17.88%-19.14%). Mean safe depth was 17.24 ± 3.14 mm in the low and normal BMI group, 18.76 ± 2.90 mm in the overweight group, and 22.01 ± 3.71 mm in the obese group. Thirteen patients (10.5%) had internal deviation of angle alpha (95% CI, 5.6%-15.3%), while 111 patients (89.5%) had external deviation (95% CI, 84.7%-94.4%). The mean internal and external deviations of angle alpha were 8.78° ± 2.92° (95% CI, 7.01°-10.55°) and 9.75° ± 3.46° (95% CI, 9.10°-10.41°), respectively. CONCLUSION: We would suggest that, when using a straight needle insertion at BL40, it is safe to advance a 25-mm needle approximately 12.5 mm, and 17.5 mm should be safe for patients with BMI greater than 28 kg/m2. Practitioners should decrease the depth of penetration when treating patients of low body weight or height.