文献速递针灸推拿中医康复

电针调节DREAM/NF-κB通路改善环磷酰胺免疫抑制小鼠

Electroacupuncture regulates the DREAM/NF-κB signalling pathway and ameliorates cyclophosphamide-induced immunosuppression in mice.
PubMed 文献 · Acupunct Med · 2019-06-13

该研究以环磷酰胺诱导的免疫抑制昆明小鼠为模型,比较手针、2 Hz、100 Hz及2/100 Hz交替电针的免疫调节效应。结果显示电针尤其2/100 Hz交替频率可改善脾胸腺指数、增强NK细胞毒性及脾细胞增殖,升高IL-2、IL-6、IL-12、TNF-α、IFN-γ并降低IL-10,同时上调p-IκBα和NF-κB、下调DREAM和IκBα。

要点

  • 2/100 Hz交替电针可能增强环磷酰胺免疫抑制小鼠的免疫应答。
  • 电针可改善脾胸腺指数、NK细胞毒性及脾细胞增殖。
  • 2/100 Hz电针可能通过激活NF-κB信号通路发挥作用。

核心结论

  • 2/100 Hz电针可能是增强环磷酰胺诱导免疫抑制小鼠免疫应答的有效方式。

研究设计与样本

  • 24只昆明小鼠腹腔注射环磷酰胺建立免疫抑制模型,另6只注射等量生理盐水作为对照。
  • 24只模型鼠随机分为手针组、2 Hz电针组、100 Hz电针组和2/100 Hz交替电针组。
  • 电针治疗3天后评估免疫应答、NK细胞毒性及细胞因子和DREAM/NF-κB表达。

主要发现

  • 电针尤其2/100 Hz交替频率可改善脾和胸腺指数,升高乳酸脱氢酶和酸性磷酸酶水平。
  • 电针促进刀豆蛋白A和脂多糖诱导的脾细胞增殖,并增强NK细胞毒性。
  • 2/100 Hz电针升高IL-2、IL-6、IL-12、TNF-α和IFN-γ水平,降低IL-10水平。
  • 2/100 Hz电针上调p-IκBα和NF-κB表达,下调DREAM和IκBα表达,提示激活NF-κB信号通路。

临床怎么用

  • 该证据来自小鼠模型,尚不能直接推导至临床免疫抑制患者的电针参数选择。

局限性

  • 样本量较小(模型鼠24只、对照6只),且为动物实验,结论外推至临床需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Immune responses inhibit invasion by pathogens and antigens. Thus, it is important to promote the immune response in immunosuppressed patients. OBJECTIVE: To examine whether electroacupuncture (EA) promotes the immune response by regulating the downstream regulatory element antagonist modulator / nuclear factor kappa B (DREAM/NF-κB) signalling pathway in a mouse model of cyclophosphamide (CP)-induced immunosuppression, and determine the most effective frequency. METHODS: Twenty-four Kunming mice were intraperitoneally injected with CP to establish an immunosuppression model and six mice were injected with the same volume of normal saline as a control. The 24 mice were randomly divided into four groups: manual acupuncture, 2 Hz EA treatment, 100 Hz EA treatment and alternating 2/100 Hz EA treatment. After EA treatment for 3 days, immune response, natural killer (NK) cell toxicity and the expression of cytokines and DREAM/NF-κB were assessed. RESULTS: EA treatment, especially at alternating 2/100 Hz frequency, improved spleen and thymus indices, increased lactate dehydrogenase and acid phosphatase levels, promoted concanavalin A- and lipopolysaccharide-induced splenocyte proliferation, increased NK cell toxicity and ameliorated CP-induced immunosuppression in mice. Additionally, 2/100 Hz EA treatment increased interleukin (IL)-2, IL-6, IL-12, tumour necrosis factor-α and interferon-γ levels and decreased IL-10 levels in CP-induced immunosuppressed mice. Finally, it was found that 2/100 Hz EA treatment increased p-IκBα and NF-κB expression and decreased DREAM and IκBα expression, suggesting that this treatment activates the NF-κB signalling pathway. CONCLUSION: 2/100 Hz EA treatment might be an effective way to enhance immune responses in CP-induced immunosuppressed mice.

来源:Acupunct Med,查看原文。版权归原作者所有。

引用

  1. Huang Z, Hu Z, Ouyang J, et al. Electroacupuncture regulates the DREAM/NF-κB signalling pathway and ameliorates cyclophosphamide-induced immunosuppression in mice. Acupunct Med. 2019. PMID: 31192694. doi:10.1136/acupmed-2017-011593

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。