钝头安慰针1mm与2mm压皮深度对患者盲法的影响
结果显示2mm压皮针使更多受试者猜测针已穿透皮肤,且小直径针增加患者盲法。
要点
- 2mm压皮安慰针使更多受试者误判为穿透针,盲法劣于1mm压皮针。
- 小直径(0.18mm)针的盲法优于大直径(0.25mm)针。
- 2mm压皮针的疼痛感与穿透针相似,设计安慰对照时需注意。
核心结论
- 2mm压皮钝头安慰针比1mm压皮针使更多受试者猜测针穿透皮肤,小直径针可提高患者盲法。
主要发现
- 0.18mm直径1mm压皮针的盲法状态为随机猜测,而0.25mm直径1mm压皮针为未盲。
- 两种直径的2mm压皮针盲法状态均为相反猜测,两种直径的穿透针均为未盲。
- 两种直径2mm压皮针报告疼痛的百分比与穿透针相似,而1mm压皮针不相似。
- 0.18mm直径2mm压皮针的得气发生频率与两种直径的穿透针相似。
关键数值与推荐
- 0.18mm直径1mm压皮针盲法指数判定为随机猜测;0.25mm直径1mm压皮针为未盲。
- 2mm压皮针(两种直径)盲法状态为相反猜测;穿透针(两种直径)为未盲。
临床怎么用
- 在需要患者盲法的针灸临床试验中,可优先选择小直径(0.18mm)1mm压皮安慰针。
- 使用2mm压皮安慰针时需注意其疼痛感与穿透针相似,可能影响盲法。
局限性
- 仅测试了两种直径和两种压皮深度,其他参数未涉及。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To investigate the influence of the depth of skin press in blunt tip placebo acupuncture needles on patient blinding and its relationship to needle diameter. METHODS: Forty healthy volunteers were enrolled as subjects for patient blinding. Four acupuncturists applied the following needles randomly at three points in each forearm: 0.18 mm and 0.25 mm diameter penetrating needles inserted to a depth of 5 mm, and 0.18 mm and 0.25 mm diameter skin-touch needles depressing the skin at the acupoint to a depth of 1 mm and 2 mm from the skin surface. The subjects reported their guesses at the nature of needles they received, and rated needle pain and de qi. A blinding index was calculated to define the success of blinding for subjects. RESULTS: The blinding status of subjects for 1 mm press needles of 0.18 mm diameter was "random guess", but "unblinded" for 1 mm press needles of 0.25 mm diameter. For 2 mm press needles of both diameters, the blinding status was "opposite guess" and the blinding status for penetrating needles of both diameters was "unblinded." The percentages of "felt pain" with 2 mm press needles of both diameters were similar to that with penetrating needles, but those were not similar for 1 mm press needles. The frequency of de qi occurrence with 2 mm press needles of 0.18 mm diameter was similar to that of penetrating needles of both diameters. CONCLUSION: Placebo needles of 2 mm press made more subjects guess that the needles penetrated the skin than 1 mm press needles. The use of small diameter needles increased patient blinding.
引用
- Takakura N, Takayama M, Nasu M, et al. Patient blinding with blunt tip placebo acupuncture needles: comparison between 1 mm and 2 mm skin press. J Integr Med. 2018. PMID: 29753429. doi:10.1016/j.joim.2018.01.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。