文献速递针灸推拿

新型假针刺装置与Park假针刺装置有效性比较的随机对照试验

Validation study comparing a novel sham acupuncture technique with Park sham acupuncture: A randomized controlled trial.
PubMed 文献 · Complement Ther Med · 2026-09-13

该随机对照试验将66名健康成人按1:1分配至新型假针刺组或Park假针刺组,在LI4和ST36穴位干预后评估穿透感、疼痛和得气。两组各项NRS均值均低于1.0,差异无统计学意义(p>0.05),新型装置对穿透感、疼痛和得气非劣于Park装置,且无不良事件报告。

要点

  • 新型假针刺装置在健康成人中与Park装置产生相似的轻微感觉反应。
  • 两组穿透感、疼痛和得气NRS均值均低于1.0,无临床意义差异。
  • 新型装置可作为针刺临床研究中的有效对照工具。

核心结论

  • 新型假针刺装置与商用Park假针刺装置在穿透感、疼痛和得气方面具有可比的有效性,可作为针刺临床研究的有效对照。

研究设计与样本

  • 随机对照试验,纳入66名健康成人,按1:1随机分配至新型假针刺组或Park假针刺组,在LI4和ST36穴位干预。

主要发现

  • 新型假针刺组与Park假针刺组在穿透感、疼痛和得气方面均无显著差异(p>0.05)。
  • 所有结局指标NRS均值均低于1.0,表明两种装置仅引起轻微感觉反应,无临床意义差异。
  • 新型装置对穿透感、疼痛和得气在统计学上非劣于Park假针刺装置。
  • 未报告不良事件。

关键数值与推荐

  • 穿透感、疼痛和得气采用11点数字评定量表(NRS)评估,0为无感觉或疼痛,10为难以忍受的感觉或疼痛。
  • 两组各项NRS均值均低于1.0。
  • 组间比较p>0.05。

临床怎么用

  • 在针刺临床研究中,新型假针刺装置可作为Park假针刺装置的替代对照工具。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Sham acupuncture serves as a control intervention in acupuncture clinical trials to minimize placebo effects and enhance methodological rigor. However, the commercially available Park sham acupuncture device has several limitations. To address these, a novel noninvasive sham acupuncture device was developed. We evaluated the validity of the new device by comparing it with the widely used Park sham acupuncture device. METHODS: This randomized controlled trial included 66 healthy adults randomly assigned (1:1) to receive the novel or Park sham acupuncture intervention at LI4 and ST36. Immediately after the intervention, participants assessed penetration sensation (perceived sensation of skin penetration), pain, and deqi at each acupoint using an 11-point Numeric Rating Scale (NRS) (0, no sensation or pain; 10, unbearable sensation or pain). Safety was evaluated by monitoring adverse events. RESULTS: The novel and Park sham acupuncture groups showed no significant differences in penetration sensation, pain, or deqi (p > 0.05). All mean outcome measure scores were below 1.0 on the NRS, indicating that both devices elicited only minimal sensory responses with no clinically meaningful differences. The novel device was statistically noninferior to the Park sham acupuncture device for penetration sensation, pain, and deqi. No adverse events were reported. CONCLUSION: The novel sham acupuncture device demonstrated comparable validity to the commercially available Park sham acupuncture device, suggesting that it can serve as a valid control in clinical studies evaluating the effects of acupuncture. The novel device is expected to contribute to future research aimed at establishing the scientific evidence base for acupuncture treatment. TRIAL REGISTRATION: Clinical Research Information Service of the Republic of Korea (registration number: KCT0010446, https://cris.nih.go.kr).

来源:Complement Ther Med,查看原文。版权归原作者所有。

引用

  1. Lim SM, Go E, Yu S, et al. Validation study comparing a novel sham acupuncture technique with Park sham acupuncture: A randomized controlled trial. Complement Ther Med. 2026. PMID: 42732822. doi:10.1016/j.ctim.2026.103435

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。