文献速递针灸推拿中医康复

电针辅助常规康复治疗脑损伤后上肢痉挛的随机对照试验

Effectiveness and safety of electroacupuncture in patients with upper limb spasticity after brain injury: a randomized controlled trial.
PubMed 文献 · Acupunct Med · 2026-05-12

本研究为单盲前瞻性两组平行随机对照试验,纳入64例脑损伤后上肢痉挛患者,随机分为常规康复组和电针加常规康复组,电针每周5次共2周。结果显示两组在改良Ashworth量表、肱二头肌剪切模量、Fugl-Meyer运动量表及Barthel指数上均无显著差异,仅1例出现针刺部位瘙痒,结论认为2周电针辅助常规康复未见额外疗效但安全性良好。

要点

  • 2周电针辅助常规康复未显著改善脑损伤后上肢痉挛。
  • 改良Ashworth量表组间差异无统计学意义(Z=-1.692,p=0.091)。
  • 电针干预在本研究中仅见1例针刺部位瘙痒,未见其他不良事件。

核心结论

  • 电针作为常规康复的附加干预,为期2周,对脑损伤后上肢痉挛未见显著疗效,但在该人群中显示安全。

研究设计与样本

  • 单盲、前瞻性、两组平行随机对照试验,共随机64例,最终符合方案分析58例。
  • 对照组仅接受常规康复,干预组接受常规康复加电针,电针每周5次,共2周。

主要发现

  • 两组治疗后较基线均有改善,但组间在改良Ashworth量表评分上无显著差异(Z=-1.692,p=0.091)。
  • 肱二头肌剪切模量短轴0°肘屈位均数差-1.079(95%CI -2.786至0.628),长轴0°肘屈位均数差-0.499(95%CI -1.699至0.700)。
  • 肱二头肌剪切模量短轴90°肘屈位均数差-0.005(95%CI -0.933至0.923),长轴90°肘屈位均数差-0.845(95%CI -1.355至1.113)。
  • Fugl-Meyer运动量表均数差-0.890(95%CI -2.243至0.462),Barthel指数均数差0.024(95%CI -2.955至3.002),组间均无显著差异。
  • 1例报告针刺部位瘙痒,试验期间及之后未观察到其他不良事件。

临床怎么用

  • 对于脑损伤后上肢痉挛患者,不应将2周电针作为常规康复之外的确定有效附加疗法。
  • 临床使用电针时需关注针刺部位瘙痒等轻微不良反应,本研究中未见其他不良事件。

局限性

  • 研究为单中心、样本量较小(随机64例,符合方案分析58例),干预周期仅2周。
  • 采用单盲设计,可能引入实施偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To explore the effectiveness and safety of electroacupuncture (EA) as an adjunct to conventional rehabilitation (CR) in patients with upper limb spasticity after brain injury. METHODS: This study was a single-blind, prospective, two-group parallel randomized controlled trial. Eligible patients were randomly divided into an intervention group and a control group. Participants in the control group received CR only, whereas those in the intervention group received CR supplemented with EA, administered five times weekly for 2 weeks. Modified Ashworth scale (MAS), shear modulus of biceps brachii muscle (BBM), Fugl-Meyer motor scale (FMMS), Barthel index (BI) and safety were assessed at baseline and after 2 weeks of treatment. RESULTS: A total of 64 patients were randomized, with 58 included in the final (per protocol) analysis. The baseline data of the two groups were comparable. Following the 2-week treatment period, improvements were observed in both groups compared to baseline. However, no significant differences were noted between the two groups in MAS (Z = -1.692, p = 0.091), BBM shear modulus short axis of 0° elbow flexion (mean difference (MD) -1.079, 95% confidence interval (CI) -2.786 to 0.628), long axis of 0° elbow flexion (MD -0.499, 95% CI -1.699 to 0.700), short axis of 90° elbow flexion (MD -0.005, 95% CI -0.933 to 0.923), long axis of 90° elbow flexion (MD -0.845, 95% CI -1.355 to 1.113), FMMS (MD -0.890, 95% CI -2.243 to 0.462) or BI (MD 0.024, 95% CI -2.955 to 3.002) scores. One participant reported an itchy sensation at the acupuncture site, with no other adverse events observed during or after the trial. CONCLUSION: EA was not effective when added to CR as a 2-week intervention for upper limb spasticity after brain injury, but appears to be a safe intervention in this population. TRIAL REGISTRATION NUMBER: ChiCTR2200060819 (Chinese Clinical Trial Registry).

来源:Acupunct Med,查看原文。版权归原作者所有。

引用

  1. Wu Z, Chen G, Hu X, et al. Effectiveness and safety of electroacupuncture in patients with upper limb spasticity after brain injury: a randomized controlled trial. Acupunct Med. 2026. PMID: 42117469. doi:10.1177/09645284261433566

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。