系统性硬化症患者指腹血流超声分类的初步研究
结果显示SSc患者0级更常见,且0级与数字溃疡(DUs)和尺动脉闭塞相关,病理阈值<2与DUs显著相关。
要点
- 指腹血流5级分类在SSc患者中可行,0级(无信号)更常见。
- 0级与当前或既往数字溃疡及尺动脉闭塞相关。
- 病理阈值<2与数字溃疡显著相关(OR 6.67)。
核心结论
- 功率多普勒超声可对SSc患者和对照的指腹血流进行半定量评估。
- 指腹血流0级与SSc数字血管病变严重标志物相关。
- 病理阈值<2与数字溃疡显著相关,需进一步验证。
研究设计与样本
- 评估指腹血流5级分类(0级无信号至4级整个指腹包括表皮下血管网)。
- 对照中评估基础状态及热水和冷水浴后的分类,SSc患者在室温下评估。
主要发现
- 对照中热水挑战后功率多普勒超声指腹血流改善(P=0.024),冷水挑战后降低(P=0.001)。
- 指腹血流与桡动脉阻力指数评估的血管舒张状态相关(Spearman相关系数=-0.50,P=0.0049)。
- SSc患者0级频率高于对照(22.1% vs 3.3%,P<0.05)。
- SSc患者中0级与当前或既往数字溃疡(P<0.05)或尺动脉闭塞(P<0.05)相关。
- 4级患者数字溃疡较少见(P<0.05)。
关键数值与推荐
- 指腹血流分类包括5级:0级无信号,4级信号检测到整个指腹包括表皮下血管网。
- 病理阈值<2(0级或1级)与数字溃疡显著相关(OR 6.67,95%CI 2.31-19.21,P<0.0001)。
临床怎么用
- 功率多普勒超声指腹血流半定量分类可用于评估SSc患者数字血管病变。
- 指腹血流0级或1级提示数字溃疡风险增高,需关注。
局限性
- 需在独立SSc人群中验证结果。
- 需将功率多普勒超声与现有数字血流评估工具比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To define a semiquantitative classification of finger pulp blood flow (FPBF) and to evaluate whether this classification could be used to assess FPBF in healthy controls and in systemic sclerosis (SSc) patients. METHODS: Thirty controls and 86 SSc patients were consecutively included. A classification of FPBF including 5 grades (from grade 0 [no signal] to 4 [signal detected on the entire finger pulp, including the subepidermal vascular network]) was evaluated. This classification was explored in basal conditions and after hand baths in hot and cold water in controls. Its relevance was also assessed at room temperature in SSc patients. RESULTS: In controls, power Doppler ultrasonography (PDUS) of FPBF was improved after hot challenge (P = 0.024), whereas cold challenge decreased FPBF (P = 0.001). FPBF correlated with the vasodilation status assessed by the resistivity index of radial arteries (Spearman's correlation coefficient = -0.50, P = 0.0049). Grade 0 was more frequent in SSc patients than in controls (22.1% versus 3.3%; P < 0.05). In SSc patients, grade 0 was associated with severity markers of the digital vasculopathy such as digital ulcers (DUs) (current or past) (P < 0.05) or ulnar artery occlusion (P < 0.05). On the other hand, DUs were less frequent in patients with grade 4 (P < 0.05). A pathologic threshold of <2 (grade 0 or 1) was significantly associated with DUs (odds ratio 6.67 [95% confidence interval 2.31-19.21], P < 0.0001). CONCLUSION: PDUS allowed a semiquantitative evaluation of FBPF in SSc patients and controls. Further studies are warranted to validate these results in independent SSc populations and to compare PDUS to existing tools assessing digital blood flow.
引用
- Lescoat A, Robin F, Belhomme N, et al. Ultrasound Classification of Finger Pulp Blood Flow in Patients With Systemic Sclerosis: A Pilot Study. Arthritis Care Res (Hoboken). 2022. PMID: 34477332. doi:10.1002/acr.24779
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。