文献速递类风湿关节炎

高分辨率外周定量CT与X线对类风湿关节炎侵蚀性分类的诊断准确性

Diagnostic accuracy of high-resolution peripheral quantitative computed tomography and X-ray for classifying erosive rheumatoid arthritis.
PubMed 文献 · Rheumatology (Oxford) · 2022-01-01

该单中心横断面研究纳入353例病程≥5年的确立期RA患者,比较优势手第2、3掌指关节HR-pQCT与44关节CR(SHS法)对侵蚀性RA的分类准确性。以CR为参考,HR-pQCT敏感度89%、特异度30%;以HR-pQCT为参考,CR敏感度85%、特异度38%;McNemar检验示两种方法敏感度无显著差异(P=0.177)。

要点

  • 仅扫描2个掌指关节的HR-pQCT与44关节CR对确立期RA侵蚀性分类的敏感度相当。
  • HR-pQCT特异度较低(30%),CR特异度亦低(38%),均易将非侵蚀误判为侵蚀。
  • 两种方法敏感度差异无统计学意义(P=0.177),提示诊断准确性可比。

核心结论

  • 仅两个掌指关节的HR-pQCT与44关节CR对确立期RA患者侵蚀性疾病的分类准确性相当。

研究设计与样本

  • 单中心横断面研究,纳入353例病程≥5年的确立期RA患者,同时行HR-pQCT与CR检查。
  • HR-pQCT评估优势手第2、3掌指关节骨侵蚀,CR按Sharp-van der Heijde法对双手、腕、足共44关节评分。

主要发现

  • CR分类为非侵蚀性RA者66例(18.7%),侵蚀性RA者287例(81.3%)。
  • 以CR为参考,HR-pQCT分类侵蚀性RA的敏感度89%(95%CI 84–92%),特异度30%(95%CI 20–43%)。
  • 以HR-pQCT为参考,CR分类侵蚀性RA的敏感度85%(95%CI 80–89%),特异度38%(95%CI 25–52%)。
  • McNemar χ2检验示两种方法分类侵蚀性RA的敏感度无显著差异(χ2=2.14,P=0.177)。

关键数值与推荐

  • HR-pQCT分类侵蚀性RA:敏感度89%(95%CI 84–92%)、特异度30%(95%CI 20–43%),参考标准为44关节CR。
  • CR分类侵蚀性RA:敏感度85%(95%CI 80–89%)、特异度38%(95%CI 25–52%),参考标准为HR-pQCT。

临床怎么用

  • 在确立期RA中,仅扫描两个掌指关节的HR-pQCT可作为44关节CR之外的侵蚀性评估选择,两者分类准确性可比。
  • 两种方法特异度均较低,临床判读侵蚀性时需结合其他影像与临床信息。

局限性

  • 单中心横断面设计,仅纳入病程≥5年的确立期RA患者。
  • HR-pQCT仅评估优势手第2、3掌指关节,未覆盖其他部位。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate whether high-resolution peripheral quantitative CT (HR-pQCT) of two metacarpophalangeal (MCP) joints can more accurately classify patients as having erosive RA compared with conventional radiography (CR) of 44 joints in the hands, wrists and feet. METHODS: In this single-centre cross-sectional study, patients with established RA (disease duration ≥5 years) were investigated by HR-pQCT and CR. The second and third MCP joints of the dominant hand were assessed for erosions by HR-pQCT. CR of the hands, wrists and feet were scored according to the Sharp-van der Heijde (SHS) method. RESULTS: In total, 353 patients were included; 66 (18.7%) patients were classified as having non-erosive RA, and 287 (81.3%) had erosive RA by CR. The sensitivity and specificity (95% CI) of HR-pQCT for classifying patients as having erosive RA when standard CR of hands, wrists and feet was used as the reference was 89% (84, 92%) and 30% (20, 43%), respectively. Using HR-pQCT as the reference, the sensitivity and specificity of CR for classifying patients having erosive RA were 85% (80, 89%) and 38% (25, 52%), respectively. McNemar's χ2 test showed no significant difference between the sensitivities of patients classified as having erosive RA by HR-pQCT or by CR (2.14, P = 0.177). CONCLUSION: The diagnostic accuracy of HR-pQCT scanning of only two MCP joints and CR of 44 joints suggests the two modalities were comparable for classifying patients with established RA as having erosive disease. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov (NCT03429426).

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Klose-Jensen R, Therkildsen J, Blavnsfeldt AG, et al. Diagnostic accuracy of high-resolution peripheral quantitative computed tomography and X-ray for classifying erosive rheumatoid arthritis. Rheumatology (Oxford). 2022. PMID: 34015091. doi:10.1093/rheumatology/keab446

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。