文献速递类风湿关节炎

超声评估类风湿关节炎结构损伤:OMERACT系统综述

Structural damage in rheumatoid arthritis assessed by musculoskeletal ultrasound: A systematic literature review by the Structural Joint Damage Task Force of the OMERACT Ultrasound Working Group.
PubMed 文献 · Semin Arthritis Rheum · 2021-03-21

该系统性文献综述由OMERACT超声工作组结构关节损伤任务组完成,检索PubMed、Embase和Cochrane Library,纳入149篇文献,评估肌肉骨骼超声在类风湿关节炎结构损伤中的测量属性。结果显示超声是敏感、可靠且可行的损伤检测工具,但效度、信度和反应性研究仍不足,需进一步验证以支持超声评分开发。

要点

  • 超声是检测RA结构损伤的敏感、可靠且可行工具。
  • 149篇纳入研究中仅21篇评估效度、34篇信度、17篇反应性。
  • 多数研究评估手部关节且采用双侧评估。

核心结论

  • 超声是检测类风湿关节炎结构损伤的敏感、可靠且可行的工具,但需进一步研究和验证。

研究设计与样本

  • 系统文献综述,检索PubMed、Embase和Cochrane Library,最终纳入149篇英文原创文章。

主要发现

  • 149篇研究中139篇(93.3%)评估骨侵蚀,24篇(16.1%)评估软骨损伤。
  • 126篇(84.6%)评估手部关节,127篇(85.2%)采用双侧评估。
  • 效度、信度和反应性分别在21篇(14.1%)、34篇(22.8%)和17篇(11.4%)研究中评估。
  • 骨赘在15篇(10.1%)研究中评估,附着点骨赘在8篇(5.4%)研究中评估。
  • 对线不良和关节强直各仅在1篇(0.9%)研究中评估。

关键数值与推荐

  • 测量属性依据OMERACT filter 2.1框架评估。
  • 大多数研究采用OMERACT超声病理定义。

临床怎么用

  • 超声可用于RA结构损伤(骨侵蚀、软骨损伤)的检测与评估。
  • 现有证据支持超声作为RA结构损伤评估的可行工具,但评分体系尚待OMERACT工作组开发。

局限性

  • 多数纳入研究为横断面研究。
  • 效度、信度和反应性评估的研究数量有限。
  • 骨侵蚀外的结构损伤(软骨、骨赘、对线不良、强直)研究较少。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To identify and synthesize the evidence for the use and measurement properties of musculoskeletal ultrasound in assessing structural joint damage in patients with rheumatoid arthritis (RA). METHODS: A systematic literature search (SLR) of the PubMed, Embase and Cochrane Library was performed. Original articles were included published in English reporting on ultrasound of bone erosion, cartilage damage and the measurement properties of ultrasound according to the OMERACT filter 2.1. RESULTS: Of the 1.495 identified articles 149 were included in the final review, most of which reported on cross-sectional studies and used the OMERACT definitions for ultrasonographic pathology. Among these, bone erosions were assessed in 139 (93.3%), cartilage damage in 24 (16.1%), enthesophytes in 8 (5.4%), osteophytes in 15 (10.1%) and malalignment and ankylosis in a single (0.9%) study, respectively. Most studies (126/149, 84.6%) assessed the joints of the hands. The overwhelming majority of studies (127/149, 85.2%) assessed structural joint damage bilaterally. Validity, reliability and responsiveness were assessed in 21 (14.1%), 34 (22.8%) and 17 (11.4%) studies, respectively. CONCLUSION: While the results of this SLR suggest that ultrasound is a sensitive, reliable and feasible tool to detect damage in RA, they also highlight the need for further research and validation. Findings of this SLR will inform the next steps of the OMERACT Ultrasound Working Group in developing an ultrasound score for assessing structural joint damage in patients with RA.

来源:Semin Arthritis Rheum,查看原文。版权归原作者所有。

引用

  1. Gessl I, Balint PV, Filippucci E, et al. Structural damage in rheumatoid arthritis assessed by musculoskeletal ultrasound: A systematic literature review by the Structural Joint Damage Task Force of the OMERACT Ultrasound Working Group. Semin Arthritis Rheum. 2021. PMID: 33810864. doi:10.1016/j.semarthrit.2021.02.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。