文献速递类风湿关节炎

基于HandScan光学光谱透射评分的类风湿关节炎疾病活动度指数开发与验证

Development and Validation of Rheumatoid Arthritis Disease Activity Indices Including HandScan (Optical Spectral Transmission) Scores.
PubMed 文献 · Arthritis Care Res (Hoboken) · 2022-06-18

本研究利用HandScan获得的光学光谱透射(OST)评分替代压痛和肿胀关节计数,开发并验证了类风湿关节炎(RA)疾病活动度指数DAS-OST。DAS-OST与DAS28的组内相关系数(ICC)在内外部验证中分别为0.88和0.82,对外部验证中缓解、低疾病活动度(LDA)和高疾病活动度(HDA)的敏感性分别为79%、91%和43%,特异性分别为92%、80%和96%。

要点

  • DAS-OST公式为:-0.44 + OST×0.03 + 男性×-0.11 + LN(ESR)×0.77 + PtGA VAS×0.03。
  • DAS-OST与DAS28的ICC在内外部验证分别为0.88和0.82,测量误差分别为0.58和0.87。
  • 外部验证中DAS-OST对缓解、LDA、HDA的敏感性分别为79%、91%、43%,特异性分别为92%、80%、96%。

核心结论

  • HandScan的OST评分联合ESR、PtGA VAS和性别构建的DAS-OST可准确评估RA疾病活动度。

研究设计与样本

  • 单中心常规接受HandScan测量且至少有一次同期OST评分和DAS28的RA患者纳入研究,数据来自病历。
  • 采用线性回归以DAS28为结局构建DAS-OST,三分之二数据用于开发、三分之一用于验证,并在另一中心进行外部验证。
  • 共提取1,505例独特RA患者的3,358次观察数据。

主要发现

  • DAS-OST定义为:-0.44 + OST×0.03 + 男性×-0.11 + LN(ESR)×0.77 + PtGA VAS×0.03。
  • DAS-OST与DAS28的ICC在内外部验证分别为0.88(95%CI 0.87-0.90)和0.82(95%CI 0.75-0.86),测量误差分别为0.58和0.87。
  • 外部验证中DAS-OST对缓解、LDA、HDA的敏感性分别为79%、91%、43%,特异性分别为92%、80%、96%。

关键数值与推荐

  • DAS-OST计算公式为:-0.44 + OST×0.03 + 男性×-0.11 + LN(ESR)×0.77 + PtGA VAS×0.03。
  • DAS-OST与DAS28的ICC在内外部验证分别为0.88(95%CI 0.87-0.90)和0.82(95%CI 0.75-0.86),测量误差分别为0.58和0.87。
  • 外部验证中DAS-OST对缓解、LDA、HDA的敏感性分别为79%、91%、43%,特异性分别为92%、80%、96%。

临床怎么用

  • 在无法进行关节计数时,可使用HandScan的OST评分联合ESR、PtGA VAS和性别计算DAS-OST评估RA疾病活动度。
  • DAS-OST对低疾病活动度敏感性较高(91%),对高疾病活动度敏感性较低(43%),需结合临床判断。

局限性

  • 研究为单中心开发数据提取自病历,外部验证样本量未报告。
  • DAS-OST对高疾病活动度的敏感性较低(43%),可能漏判高疾病活动度患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To develop and validate a composite rheumatoid arthritis (RA) disease activity index using optical spectral transmission (OST) scores obtained with the HandScan, replacing tender and swollen joint counts. METHODS: RA patients from a single center routinely undergoing HandScan measurements with at least 1 concurrent OST score and Disease Activity Score in 28 joints (DAS28) were included. Data were extracted from medical records. Linear regression analyses with the DAS28 as the outcome were performed to create a disease activity index (DAS-OST). OST score, erythrocyte sedimentation rate (ESR), and patient global assessment (PtGA) visual analog scale (VAS), sex, age, disease duration, and rheumatoid factor status were evaluated as independent variables. Final models were derived based on the statistical significance of coefficients and model fit. Of the data, two-thirds were used for development and one-third for validation; external validation was performed in a cohort from another center. Agreement between DAS-OST and DAS28 was assessed using the Bland-Altman plot method and intraclass correlation coefficient (ICC). Diagnostic value of the DAS-OST was determined for established definitions of remission, low disease activity (LDA), and high disease activity (HDA). RESULTS: Data of 3,358 observations from 1,505 unique RA patients were extracted. DAS-OST was defined as: -0.44 + OST × 0.03 + male × -0.11 + LN(ESR) × 0.77 + PtGA VAS × 0.03. The ICCs between DAS-OST and DAS28 were 0.88 (95% confidence interval [95% CI] 0.87-0.90) and 0.82 (95% CI 0.75-0.86) and measurement errors were 0.58 and 0.87 in internal and external validation, respectively. Sensitivity for remission, LDA, and HDA was 79%, 91%, and 43%, respectively, and specificity was 92%, 80%, and 96% in external validation. CONCLUSION: Using the HandScan, RA disease activity can be accurately estimated if combined with ESR, PtGA VAS, and sex into a disease activity index (DAS-OST).

来源:Arthritis Care Res (Hoboken),查看原文。版权归原作者所有。

引用

  1. Verhoeven MMA, Westgeest AAA, Schwarting A, et al. Development and Validation of Rheumatoid Arthritis Disease Activity Indices Including HandScan (Optical Spectral Transmission) Scores. Arthritis Care Res (Hoboken). 2022. PMID: 33770421. doi:10.1002/acr.24607

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。