痛风病变超声半定量评分系统的共识制定与信度检验
本研究通过OMERACT Delphi流程重新定义痛风石聚集物,并制定针对痛风石、双轨征和聚集物的半定量超声评分系统(0-3分)。重新定义的聚集物信度良好(κ值0.71和0.61),评分系统对所有病变的信度良好,阅片者内信度(κ值0.74-0.80)略高于阅片者间信度(κ值0.61-0.67)。
要点
- Delphi流程重新定义聚集物,需 overarching 原则用于患者评分。
- 制定首个痛风病变半定量超声评分系统(0-3分)。
- 静态图像测试显示所有病变信度良好。
核心结论
- 重新定义的聚集物在静态图像评估中信度良好。
- 首个共识性痛风病变半定量超声评分系统制定成功,静态图像测试中所有病变阅片者内和间信度良好。
研究设计与样本
- 随后进行基于静态超声图像的网页练习以评估信度。
主要发现
- 聚集物重新定义经过三轮Delphi达成共识,但需要 overarching 原则用于患者评分。
- 半定量超声评分系统经过两轮Delphi制定。
- 聚集物重新定义的阅片者内和间信度κ值分别为0.71和0.61。
- 评分系统所有病变的阅片者内信度κ值0.74-0.80,阅片者间信度κ值0.61-0.67。
关键数值与推荐
- Delphi共识阈值:>75%同意。
- 半定量评分系统为0-3分,针对痛风石、双轨征和聚集物。
- 聚集物重新定义阅片者内κ值0.71,阅片者间κ值0.61。
- 评分系统阅片者内κ值0.74-0.80,阅片者间κ值0.61-0.67。
临床怎么用
- 该评分系统可用于静态超声图像中痛风病变的半定量评估,信度良好。
- 下一步需在患者实时评估中验证信度。
局限性
- 信度评估基于静态图像练习,非患者实时评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0-3) for tophus, double contour and aggregates. Furthermore, the intra- and inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises. METHODS: Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system. RESULTS: Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (κ-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (κ-values 0.74-0.80) than inter-reader reliabilities (κ-values 0.61-0.67). CONCLUSION: A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was developed with good inter- and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients.
引用
- Christiansen SN, Filippou G, Scirè CA, et al. Consensus-based semi-quantitative ultrasound scoring system for gout lesions: Results of an OMERACT Delphi process and web-reliability exercise. Semin Arthritis Rheum. 2021. PMID: 33468347. doi:10.1016/j.semarthrit.2020.11.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。