干燥综合征患者唾液腺超声评分系统的患者水平信度研究
该研究评估OMERACT超声评分系统在干燥综合征患者唾液腺评估中的信度。九名超声医师对八例患者的腮腺和颌下腺图像进行两轮评分,结果显示分级评估的组内和组间信度较高,而干燥综合征标志的的信度中等。
要点
- 超声分级评估在腮腺和颌下腺均显示较高的组内和组间信度。
- 干燥综合征标志的组间信度较低,尤其颌下腺。
- 该评分系统可用于干燥综合征患者唾液腺的标准化评估。
核心结论
- 共识超声评分系统在干燥综合征患者中显示较高的组内和组间信度。
- 干燥综合征标志的信度中等。
研究设计与样本
- 九名经验丰富的超声医师对八例原发性和继发性干燥综合征患者的双侧腮腺和颌下腺进行两轮扫描和图像判读。
主要发现
- 腮腺分级0-3的平均患病率分别为43%、17%、23%和31%,颌下腺分别为28%、14%、33%和32%。
- 腮腺分级的组内加权κ范围为0.44至1,干燥综合征标志为0.64至1;颌下腺分别为0.59至1和-0.09至0.6。
- 腮腺分级的组间κ为0.62(95%CI 0.47,0.74),干燥综合征标志为0.36(95%CI 0,0.43);颌下腺分别为0.62(95%CI 0.47,0.72)和0.03(95%CI 0,0.07)。
关键数值与推荐
- 采用共识的四级半定量评分:0级正常;1级轻度不均匀,无无回声或低回声区;2级中度不均匀,伴局灶性无回声或低回声区;3级重度不均匀,伴弥漫性无回声或低回声区占据整个腺体或纤维化腺体。
- 干燥综合征标志按二分法评分(存在或不存在)。
临床怎么用
- 该超声评分系统可用于干燥综合征患者唾液腺病变的标准化评估,分级信度较高。
- 干燥综合征标志的判读信度中等,临床应用中需注意。
局限性
- 样本量较小(八例患者)。
- 未报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To assess the reliability of the consensually agreed US definitions of major salivary gland lesions and the US scoring system for salivary gland assessment in patients with SS. METHODS: Nine experienced sonographers scanned and read the US images of both parotid glands (PGs) and submandibular glands (SMGs) in eight patients with primary and secondary SS in two rounds. A consensually agreed four-grade semi-quantitative scoring was applied in B-mode for morphological lesions: grade 0, normal; grade 1, mild inhomogeneity without anechoic or hypoechoic areas; grade 2, moderate inhomogeneity with focal anechoic or hypoechoic areas; grade 3, severe inhomogeneity with diffuse an- or hypoechoic areas occupying the entire gland or fibrous gland. The presence or absence of typical SS lesions, i.e. the Sjögren's signature, was scored binary. Intra- and interreader reliabilities were computed using weighted and unweighted Cohen's and Light's κ coefficients. RESULTS: The mean prevalence of grades 0-3 in PG were 43, 17, 23 and 31% and 28, 14, 33 and 32% for the SMGs, respectively. The weighted κ for intrareader reliability ranged from 0.44 to 1 for grading and 0.64 to 1 for the Sjögren's signature of PG and 0.59 to 1 and -0.09 to 0.6 for SMGs, respectively. The interreader reliability κ for grading in PG was 0.62 (95% CI 0.47, 0.74) and for Sjögren's signature it was 0.36 (95% CI 0, 0.43); in SMG it was 0.62 (95% CI 0.47, 0.72) and 0.03 (95% CI 0, 0.07) respectively. CONCLUSIONS: The consensually agreed novel US scoring system for major salivary gland lesions showed substantial intra- and interreader reliability in patients with SS. The reliability of the Sjögren's signature was moderate.
引用
- Finzel S, Jousse-Joulin S, Costantino F, et al. Patient-based reliability of the Outcome Measures in Rheumatology (OMERACT) ultrasound scoring system for salivary gland assessment in patients with Sjögren's syndrome. Rheumatology (Oxford). 2021. PMID: 33085747. doi:10.1093/rheumatology/keaa471
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。