颈动脉超声与Framingham风险评分在银屑病关节炎中识别冠心病的比较
结果显示平均颈动脉内中膜厚度(cIMT)是CAD和阻塞性CAD(O-CAD)的独立相关变量,cIMT与FRS联合可能有助于PsA的心血管风险分层。
要点
- 平均cIMT是PsA患者CAD和O-CAD的独立相关变量。
- 检测CAD的最佳切点为FRS>5%联合平均cIMT 0.62 mm(AUC 0.71)。
- 检测O-CAD的最佳切点为FRS>10%联合平均cIMT 0.73 mm(AUC 0.71)。
核心结论
- 颈动脉超声参数包括cIMT和总斑块面积(TPA)可考虑在FRS基础上用于PsA患者的心血管风险分层。
研究设计与样本
- 采用高分辨率超声测定cIMT、斑块存在和TPA;以冠状动脉CT血管造影(CCTA)定义的CAD和O-CAD(管腔狭窄>50%)为结局。
主要发现
- 颈动脉斑块存在与CAD无显著关联;但CAD+和O-CAD+组的cIMT和TPA分别高于CAD-和O-CAD-组。
- 多变量logistic回归显示平均cIMT是CAD和O-CAD的独立解释变量,最大cIMT和TPA是O-CAD的独立解释变量。
关键数值与推荐
- 检测CAD的最佳切点:FRS>5%和平均cIMT 0.62 mm(AUC 0.71;敏感性67%;特异性76%)。
- 检测O-CAD的最佳切点:FRS>10%联合平均cIMT 0.73 mm(AUC 0.71;敏感性56%;特异性85%)。
临床怎么用
- 在PsA患者中可考虑在FRS基础上加做颈动脉超声测量cIMT和TPA以辅助心血管风险分层。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study aimed to assess the performance of carotid ultrasound (US) parameters alone or in combination with Framingham Risk Score (FRS) in discriminating patients with psoriatic arthritis (PsA) with and without coronary artery disease (CAD). METHODS: Ninety-one patients with PsA (56 males; age: 50±11 years, disease duration: 9.4±9.2 years) without overt cardiovascular (CV) diseases were recruited. Carotid intima-media thickness (cIMT), the presence of plaque and total plaque area (TPA) was determined by high-resolution US. CAD was defined as the presence of any coronary plaque on coronary CT angiography (CCTA). Obstructive-CAD (O-CAD) was defined as >50% stenosis of the lumen. RESULTS: Thirty-five (38%) patients had carotid plaque. Fifty-four (59%) patients had CAD (CAD+) and 9 (10%) patients had O-CAD (O-CAD+). No significant associations between the presence of carotid plaque and CAD were found. However, cIMT and TPA were higher in both the CAD+ and O-CAD+ group compared with the CAD- or O-CAD- groups, respectively. Multivariate logistic regression analysis revealed that mean cIMT was an independent explanatory variable associated with CAD and O-CAD, while maximum cIMT and TPA were independent explanatory variables associated with O-CAD after adjusting for covariates. The optimal cut-offs for detecting the presence of CAD were FRS >5% and mean cIMT at 0.62 mm (AUC: 0.71; sensitivity: 67%; specificity: 76%), while the optimal cut-offs for detecting the presence of O-CAD were FRS >10% in combination with mean cIMT at 0.73 mm (AUC: 0.71; sensitivity: 56%; specificity: 85%). CONCLUSION: US parameters including cIMT and TPA may be considered in addition to FRS for CV risk stratification in patients with PsA.
引用
- Cheng IT, Wong KT, Li EK, et al. Comparison of carotid artery ultrasound and Framingham risk score for discriminating coronary artery disease in patients with psoriatic arthritis. RMD Open. 2020. PMID: 32973102. doi:10.1136/rmdopen-2020-001364
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。