文献速递其他结缔组织病

超声检测系统性硬化症钙化及其与尺动脉闭塞的关联

Ultrasound Detection of Calcinosis and Association With Ulnar Artery Occlusion in Patients With Systemic Sclerosis.
PubMed 文献 · Arthritis Care Res (Hoboken) · 2021-07-27

本研究纳入43例系统性硬化症(SSc)患者,比较超声与X线检测手/腕钙化的效能,并评估尺动脉闭塞(UAO)等灌注异常标志与钙化的关联。结果显示超声检测钙化敏感且高度特异,UAO与X线识别的钙化强烈相关,即使无指端溃疡也存在关联。

要点

  • 超声检测SSc手/腕钙化敏感且高度特异,患者水平敏感度76%、特异度100%。
  • UAO与X线识别的钙化按手关联显著(OR 8.08,95%CI 2.45-26.60,P<0.001)。
  • 无指端溃疡时UAO仍与钙化相关(OR 33.00,95%CI 3.39-321.09,P=0.003)。

核心结论

  • 超声检测SSc手/腕钙化敏感且高度特异,UAO与X线识别的钙化强烈相关。

研究设计与样本

  • 纳入43例SSc患者(19例弥漫型、24例局限型),对手/腕行X线和超声检测钙化,并按患者、手和解剖分区记录。
  • 双侧超声测量UAO和指腹血流(FPBF),采用广义估计方程评估灌注异常标志与钙化的关联。

主要发现

  • X线钙化检出率39.5%,超声为30.2%。
  • 超声检测钙化的敏感度/特异度:按分区61%/95%,按手78%/98%,按患者76%/100%。
  • 左手和右手UAO分别见于30%和28%;左、右手分别有49%和44%存在≥1指FPBF缺失。
  • UAO与X线识别的钙化按手关联显著(OR 8.08,95%CI 2.45-26.60,P<0.001),FPBF和复合严重度评分不显著。
  • 无指端溃疡时UAO仍与钙化相关(OR 33.00,95%CI 3.39-321.09,P=0.003)。

临床怎么用

  • 超声可作为检测SSc手/腕钙化的敏感且高度特异的方法。
  • 发现UAO时提示钙化风险增加,即使无指端溃疡也应关注钙化评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate the ability of ultrasound (US) compared to radiographs to detect calcinosis in hands/wrists of patients with systemic sclerosis (SSc), and to assess US markers of pathologic perfusion. METHODS: Patients with SSc were evaluated for calcinosis in the hands/wrists by radiograph and US. The presence or absence of calcinosis was recorded by patient, hand, and anatomic zone; sensitivity and specificity for calcinosis detection by US versus radiographs was determined. Bilateral US vascular measurements of ulnar artery occlusion (UAO) and finger pulp blood flow (FPBF) were obtained. For each hand, associations between markers of pathologic blood flow (UAO, FPBF, and a composite severity score of UAO and FPBF) and the presence of calcinosis were assessed using generalized estimating equations. RESULTS: Of 43 patients with SSc (19 diffuse, 24 limited), 39.5% had calcinosis on radiographs compared to 30.2% on US. Sensitivity and specificity for US, respectively, were 61% and 95% by zone, 78% and 98% by hand, and 76% and 100% by patient. UAO was seen in 30% and 28% of left and right hands, respectively; FPBF was absent in ≥1 digit of the left and right hands in 49% and 44%, respectively. UAO was associated with radiograph-identified calcinosis by hand (odds ratio [OR] 8.08 [95% confidence interval (95% CI) 2.45-26.60], P < 0.001), whereas FPBF and the composite severity score were not significant. UAO was associated with calcinosis even in the absence of digital ulcers (OR 33.00 [95% CI 3.39-321.09], P = 0.003). CONCLUSION: US was sensitive and highly specific in detecting calcinosis in SSc. UAO was strongly associated with radiograph-identified calcinosis.

来源:Arthritis Care Res (Hoboken),查看原文。版权归原作者所有。

引用

  1. Fairchild R, Chung M, Sharpless L, et al. Ultrasound Detection of Calcinosis and Association With Ulnar Artery Occlusion in Patients With Systemic Sclerosis. Arthritis Care Res (Hoboken). 2021. PMID: 32475057. doi:10.1002/acr.24327

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。