高光谱成像用于系统性硬化症皮肤评估的初步研究
该初步研究纳入31例系统性硬化症(SSc)患者,比较皮肤评分、超声与高光谱成像(HSI)区分SSc与健康对照的能力,发现光谱角映射器(SAM)与皮肤评分及真皮厚度正相关,且在皮肤评分正常的SSc患者中仍显著高于健康对照,检测SSc的曲线下面积(AUC)最高(0.812)。结论提示HSI可作为评估SSc皮肤改变的新型无创方法。
要点
- SAM与皮肤评分及真皮厚度正相关,皮肤评分正常者SAM仍高于健康对照。
- SAM检测SSc的AUC为0.812,高于皮肤评分、厚度及应变比。
- 光谱图波形递增变化可反映皮肤紧绷严重程度。
核心结论
- SAM与皮肤评分相关,且对亚临床病变足够敏感,HSI可作为评估SSc皮肤改变的新型无创方法。
研究设计与样本
- 初步研究,共纳入31例SSc患者,采用短波红外光检测HSI的光谱角映射器(SAM),并以皮肤评分、超声检测真皮厚度及应变弹性成像评估皮肤严重程度,用Spearman相关及ROC曲线进行比较。
主要发现
- SAM与皮肤评分及真皮厚度呈正相关。
- 皮肤评分正常的SSc患者SAM值仍显著高于健康对照。
- SAM检测SSc的AUC为0.812(P < 0.001),皮肤评分为0.712(P < 0.001),厚度为0.585(P = 0.009),弹性成像应变比为0.522(P = 0.510)。
- 皮肤紧绷严重程度由光谱图波形的递增变化反映。
关键数值与推荐
- SAM检测SSc的AUC:0.812,P < 0.001;皮肤评分AUC:0.712,P < 0.001;厚度AUC:0.585,P = 0.009;应变比AUC:0.522,P = 0.510。
临床怎么用
- 对于皮肤评分正常但疑有亚临床皮肤改变的SSc患者,可考虑用HSI的SAM进行无创补充评估。
局限性
- 原文未报告局限性内容。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Hyperspectral imaging (HSI) is a novel technology for obtaining quantitative measurements from transcutaneous spatial and spectral information. In patients with SSc, the severity of skin tightness is associated with internal organ involvement. However, clinical assessment using the modified Rodnan skin score is highly variable and there are currently no universal standardized protocols. This study aimed to compare the ability to differentiate between SSc patients and healthy controls using skin scores, ultrasound and HSI. METHODS: Short-wave infrared light was utilized to detect the spectral angle mapper (SAM) of HSI. In addition, skin severity was evaluated by skin scores, ultrasound to detect dermal thickness and strain elastography. Spearman's correlation was used for assessing skin scores, strain ratio, thickness and SAM. Comparisons of various assessment tools were performed by receiver operating characteristic curves. RESULTS: In total, 31 SSc patients were enrolled. SAM was positively correlated with skin scores and dermal thickness. In SSc patients with normal skin scores, SAM values were still significantly higher than in healthy controls. SAM exhibited the highest area under the curve (AUC: 0.812, P < 0.001) in detecting SSc compared with skin scores (AUC: 0.712, P < 0.001), thickness (AUC: 0.585, P = 0.009) and strain ratio by elastography (AUC: 0.522, P = 0.510). Moreover, the severity of skin tightness was reflected by the incremental changes of waveforms in the spectral diagrams. CONCLUSION: SAM was correlated with skin scores and sufficiently sensitive to detect subclinical disease. HSI can be used as a novel, non-invasive method for assessing skin changes in SSc.
引用
- Chen YM, Lai KL, Chen HH, et al. Hyperspectral imaging for skin assessment in systemic sclerosis: a pilot study. Rheumatology (Oxford). 2020. PMID: 32215624. doi:10.1093/rheumatology/keaa067
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。