文献速递脊柱关节炎

整合纵向分析不损害精度并减少影像学结局研究中的偏倚:DESIR队列5年比较分析

Integrated longitudinal analysis does not compromise precision and reduces bias in the study of imaging outcomes: A comparative 5-year analysis in the DESIR cohort.
PubMed 文献 · Semin Arthritis Rheum · 2020-03-03

基于DESIR队列中符合ASAS中轴型脊柱关节炎标准的413例患者,比较整合纵向分析(纳入所有可用的影像评分)与完成者分析(仅5年随访完成者)对影像学变化估计精度的影响。结果显示整合分析更包容且精度与完成者分析相似;对低发生率结局(如5年内mNY阳性),整合分析捕获的发生率更高且更精确(年变化百分比1.1 vs 1.2)。

要点

  • 整合纵向分析利用所有可用影像数据,不损害变化估计的精度。
  • 对低发生率影像结局,整合分析可能提高检出变化的统计效能。
  • 该分析方法无需额外假设,可减少因缺失数据导致的偏倚。

核心结论

  • 整合纵向分析不危及影像参数变化估计的精度,并可能对低发生率变化提供更高统计效能。

研究设计与样本

  • DESIR队列中符合ASAS axSpA标准的413例患者,基线和1、2、5年采集骶髂关节和脊柱X线及MRI,每张影像由2或3名阅片者分3个阅片波次评分。
  • 比较三种分析方式:整合分析(纳入所有波次至少1名阅片者至少1个评分的所有患者)、仅完成者分析(5年随访患者,个体阅片者评分)和完成者组合算法分析。

主要发现

  • 整合分析比两种完成者分析更包容,变化估计的精度水平相似。
  • 对低发生率结局(如5年内mNY阳性),整合分析捕获的发生率更高且更精确:年变化百分比(95%CI)为1.1(0.7; 1.5),完成者组合算法分析为1.2(0.5; 1.8)。

关键数值与推荐

  • 低发生率结局示例:5年内mNY阳性的年变化百分比(95%CI)整合分析为1.1(0.7; 1.5),完成者组合算法分析为1.2(0.5; 1.8)。

临床怎么用

  • 在纵向影像学研究中,可采用整合分析利用所有可用评分数据,以减少完成者分析可能引入的偏倚。
  • 对低发生率影像结局,整合分析可能提高检测变化的统计效能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess if an integrated longitudinal analysis using all available imaging data affects the precision of estimates of change in patients with axial spondyloarthritis (axSpA), with completers analysis as reference standard. METHODS: Patients from the DESIR cohort fulfilling the ASAS axSpA criteria were included. Radiographs and MRIs of the sacroiliac joints and spine were obtained at baseline, 1, 2 and 5 years. Each image was scored by 2 or 3 readers in 3 'reading-waves' (or campaigns). Each outcome was analyzed: i. According to a 'combination algorithm' (e.g. '2 out of 3' for binary scores); and ii. Per reader. Change over time was analyzed with generalized estimating equations by 3 approaches: (a)'integrated-analysis' (all patients with ≥1 score from ≥1 reader from all waves); (b1)Completers-only analysis (patients with 5-year follow-up, using scores from individual readers); (b2)Completers analysis using a 'combination algorithm' (as (b1) but with combined scores). Approaches (b1) and (b2) were considered the 'reference'. RESULTS: In total, 413 patients were included. The 'integrated analysis' was more inclusive with similar levels of precision of the change estimates as compared to both completers analyses. In fact, for low-incident outcomes (e.g.% mNY-positive over 5-years), an increased incidence was 'captured', with more precision, by the 'integrated analysis' compared to the completers analysis with combined scores (% change/year (95%CI): 1.1 (0.7; 1.5) vs 1.2 (0.5; 1.8), respectively). CONCLUSION: An efficient and entirely assumption-free 'integrated analysis' does not jeopardize precision of the estimates of change in imaging parameters and may yield increased statistical power for detecting changes with low incidence.

来源:Semin Arthritis Rheum,查看原文。版权归原作者所有。

引用

  1. Sepriano A, Ramiro S, van der Heijde D, et al. Integrated longitudinal analysis does not compromise precision and reduces bias in the study of imaging outcomes: A comparative 5-year analysis in the DESIR cohort. Semin Arthritis Rheum. 2020. PMID: 32209237. doi:10.1016/j.semarthrit.2020.02.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。