超声诊断大血管型巨细胞动脉炎:以FDG PET/CT为参考标准的诊断准确性
前瞻性评估腋动脉超声以FDG PET/CT为参考标准诊断大血管型巨细胞动脉炎(LV-GCA)的准确性。腋动脉超声诊断LV-GCA敏感度76%、特异度100%;腋动脉内膜中层厚度1.0mm截断值敏感度74%、特异度92%。联合颅动脉评估可将敏感度从71%提高至97%。
要点
- 腋动脉超声诊断LV-GCA敏感度76%、特异度100%。
- 腋动脉内膜中层厚度1.0mm截断值敏感度74%、特异度92%。
- 联合颅动脉评估使全部GCA患者敏感度从71%升至97%。
核心结论
- 腋动脉超声对LV-GCA诊断具有高准确性,建议作为所有疑似GCA患者的一线确诊检查。
研究设计与样本
- 前瞻性研究纳入年龄≥50岁、炎症标志物升高且有潜在GCA症状的患者,排除免疫抑制治疗中或既往诊断GCA/PMR者,治疗前完成检查。
- LV-GCA参考诊断为临床诊断GCA且PET证实大血管炎症;符合ACR标准的GCA患者视为颅型GCA(c-GCA);无GCA者为对照。
主要发现
- 腋动脉超声诊断LV-GCA的敏感度为76%,特异度为100%。
- 腋动脉内膜中层厚度截断值1.0mm诊断LV-GCA的敏感度为74%,特异度为92%。
- 在全部GCA患者中,联合腋动脉超声与颅动脉评估使敏感度从71%提高至97%。
- 颅动脉PET/CT诊断c-GCA的敏感度为78%,特异度为100%。
关键数值与推荐
- 腋动脉超声诊断LV-GCA:敏感度76%,特异度100%。
- 腋动脉内膜中层厚度1.0mm截断值:敏感度74%,特异度92%。
- 联合颅动脉评估(全部GCA患者):敏感度从71%提高至97%。
- 颅动脉PET/CT诊断c-GCA:敏感度78%,特异度100%。
临床怎么用
- 基于EULAR推荐,提出以超声作为一线确诊检查的诊断流程,适用于所有疑似GCA患者,而不仅限于疑似c-GCA者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The diagnostic accuracy of axillary artery US in the diagnosis of large-vessel (LV)-GCA using 18F-fluorodeoxyglucose (FDG) PET/CT as reference standard was prospectively evaluated in GCA-suspected patients. As an exploratory analysis, the diagnostic accuracy of cranial artery FDG PET/CT was evaluated. METHODS: Briefly, the inclusion criteria were age ≥50 years, raised inflammatory markers and potential GCA symptoms. Patients in immunosuppressive therapy or with a previous diagnosis of GCA or PMR were excluded. Examinations were performed pre-treatment. LV-GCA reference diagnosis was a clinical diagnosis of GCA and PET-proven LV inflammation. GCA patients fulfilling ACR criteria were considered as cranial-GCA (c-GCA). Patients without GCA were considered controls. Receiver operating characteristic curve analysis of the US-measured axillary intima-media thickness was performed. FDG uptake in temporal, maxillary and vertebral arteries was also assessed. RESULTS: Forty-six patients were diagnosed with LV-GCA, 10 with isolated c-GCA, and in 34 patients GCA was dismissed. Axillary US yielded a sensitivity of 76% and a specificity of 100% for LV-GCA. An axillary intima-media thickness cut-off of 1.0 mm yielded a sensitivity of 74% and a specificity of 92%. Adding LV US to temporal assessment increased sensitivity from 71% to 97% (all GCA patients). Cranial artery PET showed a diagnostic sensitivity of 78% and specificity of 100% for c-GCA. CONCLUSION: Axillary artery US shows high accuracy for the LV-GCA diagnosis. Building upon the recent EULAR recommendations, we propose a diagnostic algorithm with US as the first-line confirmatory test, not only in c-GCA-suspected patients, but in all patients suspected of GCA.
引用
- Nielsen BD, Hansen IT, Keller KK, et al. Diagnostic accuracy of ultrasound for detecting large-vessel giant cell arteritis using FDG PET/CT as the reference. Rheumatology (Oxford). 2020. PMID: 31808526. doi:10.1093/rheumatology/kez568
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。