文献速递脊柱关节炎

超声能量多普勒显示滑车增强可定位银屑病指炎病变

Power Doppler enhancement of accessory pulleys confirming disease localization in psoriatic dactylitis.
PubMed 文献 · Rheumatology (Oxford) · 2020-01-01

研究纳入58例银屑病关节炎指炎患者,对指炎指及对侧指的第2至第4指滑车行超声检查,用Leeds Dactylometer测量厚度。结果发现指炎指滑车内能量多普勒信号较对侧更常见,并与A1、A2、A4滑车增厚相关,提示辅助滑车在指炎相关腱鞘炎及腱外病变中起关键作用。

要点

  • 指炎指滑车内能量多普勒信号较对侧更常见,且与A1、A2、A4滑车增厚相关。
  • 几乎全部病例存在腱周水肿,82.6%指炎指有屈肌腱腱鞘炎,其中65.2%肌腱见能量多普勒信号。
  • 辅助滑车虽小且相对无血管,但在活动性银屑病指炎中可出现能量多普勒改变。

核心结论

  • 辅助滑车在活动性银屑病指炎中可出现能量多普勒改变,支持其在指炎相关腱鞘炎和腱外病变中起关键作用。

研究设计与样本

  • 对58例银屑病关节炎指炎患者行第2至第4指滑车超声检查,包括指炎指与对侧指,并用Leeds Dactylometer测量厚度。

主要发现

  • 指炎指滑车能量多普勒信号较对侧更常见,A1滑车51%、A2滑车22%、A4滑车12%,对侧A1、A2、A4各1个(1.7%)。
  • 几乎全部病例有腱周水肿,82.6%指炎指存在屈肌腱腱鞘炎,65.2%屈肌腱见能量多普勒信号。
  • 58例中34例为急性指炎、24例为慢性指炎,45/58(77%)临床评估有压痛。

临床怎么用

  • 对银屑病指炎患者可行超声评估辅助滑车能量多普勒信号与厚度,辅助定位指炎相关病变。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The digital accessory pulleys are highly mechanically stressed mini-entheses that are thickened in patients with a history of PsA-related dactylits. This study explored whether these pulleys are involved in PsA dactylitis as assessed by intra-pulley US power Doppler changes. METHODS: Fifty-eight PsA patients with dactylitis had US of the second to fourth digits for pulleys of the dactylitic and contralateral digits. The Leeds Dactylometer was used for thickness measurement. The presence of digital pain, tenderness, and swelling in the dactylitis finger and in the contralateral side was evaluated. RESULTS: We recruited 34 patients with acute and 24 patients with chronic dactylitis, 45/58 (77%) of which had tenderness on clinical assessment. Intra-pulley power Doppler was more frequently found in the dactylitic digits compared with contralateral sides and linked to A1, A2 and A4 pulleys thickening [power Doppler signals in A1 pulley (51%), A2 (22%) and A4 (12%) in dactylitic digit; compared with 1 A1, A2 and A4 pulleys each in the contralateral side (1.7%)]. Almost all cases had peri-tendinous oedema, and 82.6% of dactylitic digits had flexor tenosynovitis with power Doppler signals in 65.2% of flexor tendons. CONCLUSION: Despite their small size and relatively avascular, the accessory pulleys exhibit power Doppler change in active Psoriatic dactylitis, supporting a pivotal role in dactylitis-related tenosynovitis and extra-tendinous disease.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Tinazzi I, McGonagle D, Macchioni P, et al. Power Doppler enhancement of accessory pulleys confirming disease localization in psoriatic dactylitis. Rheumatology (Oxford). 2020. PMID: 31794000. doi:10.1093/rheumatology/kez549

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。