超高频超声评估系统性硬化症皮肤受累的初步研究
结果显示超高频超声可精确测量真皮厚度,手指真皮厚度患者显著高于对照,前臂则显著低于对照,真皮与皮下组织纹理分析可区分SSc与健康人。
要点
- 超高频超声可精确识别并测量真皮厚度,观察者间变异好至优秀。
- 手指真皮厚度SSc患者显著高于健康对照,前臂则显著低于对照。
- 真皮与皮下组织纹理计算分析可区分SSc与健康受试者(AUC>0.7)。
核心结论
- 超高频超声能详细显示皮肤各层、可靠测量真皮厚度,并可通过真皮与皮下组织纹理特征区分SSc与健康人。
主要发现
- 手指真皮厚度患者显著高于对照(P < 0.05),前臂真皮厚度患者显著低于对照(P < 0.001)。
- 真皮厚度观察者间变异好至优秀(前臂ICC = 0.754;手指ICC = 0.699;手ICC = 0.602)。
- 真皮与皮下组织纹理计算分析可区分SSc与健康受试者(AUC > 0.7)。
关键数值与推荐
- 手指真皮厚度比较P < 0.05,前臂真皮厚度比较P < 0.001。
- 真皮厚度观察者间ICC:前臂0.754、手指0.699、手0.602。
- 纹理特征区分SSc与健康受试者的AUC > 0.7。
临床怎么用
- 超高频超声可用于SSc皮肤厚度与纹理的客观评估,辅助区分SSc与健康人,但需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: High frequency ultrasound allows visualization of epidermis, dermis and hypodermis, precise measurement of skin thickness, as well as assessment of skin oedema, fibrosis and atrophy. The aim of this pilot cross-sectional observational study was to assess the performance and multiobserver variability of ultra-high-frequency (UHF) (50 MHz) ultrasound (US) in measuring skin thickness as well as the capacity of UHF-derived skin features to differentiate SSc patients from healthy controls. METHODS: Twenty-one SSc patients (16 limited and five diffuse SSc) and six healthy controls were enrolled. All subjects underwent US evaluation by three experts at three anatomical sites (forearm, hand and finger). Dermal thickness was measured and two rectangular regions of interest, one in dermis and one in hypodermis, were established for texture feature analysis. RESULTS: UHF-US allowed a precise identification and measurement of the thickness of the dermis. The dermal thickness in the finger was significantly higher in patients than in controls (P < 0.05), while in the forearm it was significantly lower in patients than in controls (P < 0.001). Interobserver variability for dermal thickness was good to excellent [forearm intraclass correlation coefficient (ICC) = 0.754; finger ICC = 0.699; hand ICC = 0.602]. Texture computed analysis of dermis and hypodermis was able to discriminate between SSc and healthy subjects (area under the curve >0.7). CONCLUSION: These preliminary data show that skin UHF-US allows a very detailed imaging of skin layers, a reliable measurement of dermal thickness, and a discriminative capacity between dermis and hypodermis texture features in SSc and healthy subjects.
引用
- Naredo E, Pascau J, Damjanov N, et al. Performance of ultra-high-frequency ultrasound in the evaluation of skin involvement in systemic sclerosis: a preliminary report. Rheumatology (Oxford). 2020. PMID: 31665474. doi:10.1093/rheumatology/kez439
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。