系统性硬化症患者间质性肺病的PET定量评估
本研究分析8例SSc患者(含5例ILD)及8例SLE、4例pSS无ILD患者的18F-FDG PET/CT与高分辨率CT,发现SSc-ILD患者背基底区SUVmean和B/A-p比值较无ILD的SSc、SLE及pSS升高,且摄取增高对应磨玻璃影和网格影。
要点
- SSc-ILD患者背基底区SUVmean较无ILD的SSc、SLE及pSS升高。
- B/A-p比值在SSc-ILD较SLE和pSS升高,较无ILD的SSc呈边缘升高。
- 背基底区摄取增高和B/A-t比值升高对应高分辨率CT的磨玻璃影和网格影。
核心结论
- 18F-FDG PET/CT半定量评估能区分SSc的ILD与未受累肺组织,提示其可能作为SSc-ILD疾病活动性的新生物标志物。
研究设计与样本
- 分析8例SSc患者(包括5例ILD)的18F-FDG PET/CT和高分辨率CT扫描。
- 纳入8例SLE和4例pSS无ILD患者作为参照组。
- 每例患者在 apical、medial 和 dorsobasal 肺水平绘制共22个感兴趣区,测量SUVmean并计算B/A和M/A比值。
主要发现
- SSc-ILD患者背基底ROI的SUVmean较无ILD的SSc升高(P=0.04),B/A-p比值呈边缘升高(P=0.07)。
- SSc-ILD患者背基底ROI的SUVmean较SLE升高(P=0.003),B/A-p比值较SLE升高(P=0.002)。
- SSc-ILD患者背基底ROI的SUVmean较pSS升高(P=0.03),B/A-p比值较pSS升高(P=0.02)。
- 背基底肺摄取增高和B/A-t比值升高对应高分辨率CT上的磨玻璃影和网格影。
临床怎么用
- 对于SSc患者,可考虑使用18F-FDG PET/CT半定量评估肺内代谢活性,辅助区分ILD与未受累肺组织。
- 背基底区SUVmean和B/A比值可能有助于提示SSc-ILD的疾病活动性,但需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The reversibility of interstitial lung disease (ILD) in SSc is difficult to assess by current diagnostic modalities and there is clinical need for imaging techniques that allow for treatment stratification and monitoring. 18F-Fluorodeoxyglucose (FDG) PET/CT scanning may be of interest for this purpose by detection of metabolic activity in lung tissue. This study aimed to investigate the potential role of 18F-FDG PET/CT scanning for the quantitative assessment of SSc-related active ILD. METHODS: 18F-FDG PET/CT scans and high resolution CT scans of eight SSc patients, including five with ILD, were analysed. For comparison, reference groups were included: eight SLE patients and four primary Sjögren's syndrome (pSS) patients, all without ILD. A total of 22 regions of interest were drawn in each patient at apical, medial and dorsobasal lung levels. 18F-FDG uptake was measured as mean standardized uptake value (SUVmean) in each region of interest. Subsequently, basal/apical (B/A) and medial/apical (M/A) ratios were calculated at patient level (B/A-p and M/A-p) and at tissue level (B/A-t and M/A-t). RESULTS: SUVmean values in dorsobasal ROIs and B/A-p ratios were increased in SSc with ILD compared with SSc without ILD (P = 0.04 and P = 0.07, respectively), SLE (P = 0.003 and P = 0.002, respectively) and pSS (P = 0.03 and P = 0.02, respectively). Increased uptake in the dorsobasal lungs and increased B/A-t ratios corresponded to both ground glass and reticulation on high resolution CT. CONCLUSION: Semi-quantitative assessment of 18F-FDG PET/CT is able to distinguish ILD from non-affected lung tissue in SSc, suggesting that it may be used as a new biomarker for SSc-ILD disease activity.
引用
- Peelen DM, Zwezerijnen BGJC, Nossent EJ, et al. The quantitative assessment of interstitial lung disease with positron emission tomography scanning in systemic sclerosis patients. Rheumatology (Oxford). 2020. PMID: 31642912. doi:10.1093/rheumatology/kez483
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。