文献速递痛风与晶体性关节病

双能CT显示痛风尿酸盐沉积呈对称性多关节分布

Radiologic evidence of symmetric and polyarticular monosodium urate crystal deposition in gout - A cluster pattern analysis of dual-energy CT.
PubMed 文献 · Semin Arthritis Rheum · 2019-07-11

该研究对153例长期接受别嘌醇治疗的痛风患者进行双能CT扫描,评估尿酸盐沉积和骨侵蚀的聚集模式。结果显示尿酸盐沉积在双手/腕、双足/踝和双膝多部位聚集,且同一关节对侧对称受累的关联最强(调整OR分别为26.1、46.9和9.9),支持痛风为对称性多关节病的观点。

要点

  • 长期痛风患者尿酸盐沉积呈对称性多关节聚集模式
  • 同一关节对侧对称受累的关联强度最高(调整OR 9.9–46.9)
  • 有尿酸盐沉积的部位发生骨侵蚀的可能性高8倍

核心结论

  • 在长期接受降尿酸治疗的痛风患者中,尿酸盐沉积和骨侵蚀在双手/腕、双足/踝和双膝呈高度对称的多关节分布,支持痛风为对称性多关节病的概念。

研究设计与样本

  • 对153例每日服用别嘌醇≥300 mg且≥3个月的痛风患者进行双手/腕、双足/踝和双膝的双能CT扫描,由两名放射科医生在预设部位评估尿酸盐沉积和骨侵蚀的聚集模式。

主要发现

  • 尿酸盐沉积(67%)在双手/腕、双足/踝和双膝多部位聚集的程度超出随机预期(三个区域均p<0.001)。
  • 在双足/踝,骨侵蚀也呈聚集性分布(p<0.001)。
  • 某一关节存在尿酸盐沉积与对侧同一关节对称受累的关联最强,双手/腕、双足/踝和双膝的调整OR分别为26.1、46.9和9.9。
  • 双足/踝骨侵蚀同样高度对称(调整OR 91.4)。
  • 有尿酸盐沉积的部位发生骨侵蚀的可能性是无沉积部位的8倍。

临床怎么用

  • 对于长期痛风患者,双能CT可识别尿酸盐沉积的对称性多关节分布模式,提示临床应关注对侧对应关节的评估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To determine the clustering patterns of monosodium urate (MSU) crystal deposition and bone erosions among patients with gout requiring urate-lowering therapy (ULT) using dual-energy CT (DECT). METHODS: DECT scans of bilateral hands/wrists, feet/ankles, and knees were obtained on 153 patients with gout on allopurinol ≥300 mg daily for ≥3 months. Two radiologists assessed the images at pre-specified sites (15 in the hands/wrists, 12 in the feet/ankles, 4 in the knees). Clustering patterns of MSU crystal deposition and bone erosions were evaluated. RESULTS: Among 153 patients with gout (mean duration, 15 years) on allopurinol (mean duration, 5 years), MSU crystal deposition (67%) affected multiple sites in the hands/wrists, feet/ankles, and knees more often than would be expected by chance (p<0.001 for all 3 regions). In the feet/ankles, bone erosions were also observed in a clustered manner (p<0.001). Presence of MSU crystal deposition at a particular joint was most strongly associated with symmetric involvement of the same joint of the opposite extremity in the hands/wrists, feet/ankles, and knees (adjusted odds ratio (OR) 26.1, 46.9, and 9.9, respectively). Similarly, presence of erosions in the feet/ankles was highly symmetric (adjusted OR 91.4). Erosions were 8-fold more likely to be present in sites with MSU crystal deposition compared to those without. CONCLUSION: Among patients with longstanding gout on ULT, MSU crystal deposition and bone erosions affect multiple joints within the hands/wrists, feet/ankles, and knees in a highly symmetric manner. These radiologic data support the notion of MSU crystal deposition in gout as a symmetric polyarthropathy.

来源:Semin Arthritis Rheum,查看原文。版权归原作者所有。

引用

  1. Yokose C, Dalbeth N, Wei J, et al. Radiologic evidence of symmetric and polyarticular monosodium urate crystal deposition in gout - A cluster pattern analysis of dual-energy CT. Semin Arthritis Rheum. 2019. PMID: 31371194. doi:10.1016/j.semarthrit.2019.07.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。