文献速递血管炎

FDG-PET/CT与超声诊断巨细胞动脉炎:一致性或互补性影像方法

[18F]FDG positron emission tomography and ultrasound in the diagnosis of giant cell arteritis: congruent or complementary imaging methods?
PubMed 文献 · Rheumatology (Oxford) · 2020-01-01

该研究纳入102例疑似巨细胞动脉炎(GCA)患者,均接受扩展血管超声和FDG-PET/CT检查,其中68例确诊GCA、34例排除。两种影像方法诊断准确性相当,但单血管区域常不一致,提示二者互补,序贯联合可使诊断率提高16-20%。

要点

  • FDG-PET/CT与超声对GCA诊断准确性相当。
  • 两种影像在单血管区域常不一致,仅20/136个阳性节段均阳性。
  • 联合第二种影像可使诊断率提高16-20%。

核心结论

  • PET/CT测量血管壁代谢与超声评估血管壁形态对GCA诊断准确性相当,但二者在单一血管区域常不一致,应视为互补方法,联合第二种影像可使诊断率提高16-20%。

研究设计与样本

  • 选自2006年12月至2012年8月疑似GCA队列中连续接受扩展血管超声和PET/CT诊断检查的患者,共纳入102例,68例确诊GCA、34例排除(对照)。

主要发现

  • 超声血管炎改变最常见于颞动脉(左右各32例阳性),其次为腘动脉(右10、左9)和锁骨下/腋动脉(右7、左8)。
  • PET/CT血管炎最常见于椎动脉(右23、左33)和颈总动脉(右32、左24),其次为锁骨下动脉(右16、左18)、胸主动脉(17)和腹主动脉(23)。
  • 68例GCA中37例PET/CT与超声均显示血管炎,11例仅超声阳性,14例仅PET/CT阳性。
  • 超声特异性更高(假阳性1例 vs PET/CT假阳性5例)。
  • 单节段水平仅136个阳性节段中的20个在两种影像中均阳性。

临床怎么用

  • 对疑似GCA患者,PET/CT与超声诊断准确性相当,但单血管区域常不一致,建议将二者视为互补方法,序贯联合第二种影像可使诊断率提高16-20%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: [18F]Fluorodeoxyglucose (FDG)-PET/CT and US are both well established for diagnosing GCA. The present study investigates their accuracy and whether they provide overlapping or complementary information in a cohort of patients presenting with suspicion of GCA. METHODS: We selected consecutive patients from our cohort of suspected GCA cases that underwent both extended vascular US and PET/CT for diagnostic work-up between December 2006 and August 2012. RESULTS: A total of 102 patients were included. Diagnosis of GCA was confirmed in 68 patients and excluded in 34 patients (controls). Vasculitic changes in US were most often found in the temporal artery with 32 positive findings on each side, followed by the popliteal artery (10 right, 9 left) and the subclavian/axillary artery (7 right, 8 left). By contrast, PET/CT showed vasculitis most frequently in the vertebral (23 right, 33 left) and common carotid arteries (32 right, 24 left), followed by the subclavian arteries (16 right, 18 left), and the thoracic (17) and abdominal aorta (23). In 37/68 GCA patients PET/CT and US both revealed vasculitic findings, 11/68 had positive findings in US only and 14/68 in PET/CT only. Specificity of US was higher (one false-positive vs five false-positive in PET/CT). On a single segment level, only 20 of 136 positive segments were positive in both imaging modalities. CONCLUSION: PET/CT measuring vessel wall metabolism and US vessel wall morphology showed a comparable diagnostic accuracy for GCA. However PET/CT and US were often discrepant within single vascular regions. Thus PET/CT and US should be considered as complementary methods, with a second imaging modality increasing the diagnostic yield by 16-20%.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Imfeld S, Aschwanden M, Rottenburger C, et al. [18F]FDG positron emission tomography and ultrasound in the diagnosis of giant cell arteritis: congruent or complementary imaging methods? Rheumatology (Oxford). 2020. PMID: 31436837. doi:10.1093/rheumatology/kez362

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。