文献速递脊柱关节炎

银屑病关节炎低疾病活动度定义的超声评估

Evaluating current definitions of low disease activity in psoriatic arthritis using ultrasound.
PubMed 文献 · Rheumatology (Oxford) · 2019-01-01

结果显示除DAS28-CRP外,其余LDA标准可区分高与低超声活动;无超声炎症征象但被归为较高疾病活动度的患者,主要原因是疼痛及疼痛相关条目。

要点

  • DAPSA、PASDAS、CPDAI和MDA的LDA界值可区分高与低超声活动度。
  • DAS28-CRP的LDA界值不能区分超声活动度高低。
  • 疼痛及疼痛相关条目是无超声炎症患者被归为较高活动度的主因。

核心结论

  • DAPSA、PASDAS、CPDAI和MDA的LDA界值能区分高与低超声活动度,DAS28-CRP则不能。
  • 无超声炎症征象的PsA患者被归为较高疾病活动度,主要归因于疼痛及疼痛相关条目。

研究设计与样本

  • 超声检查覆盖68个关节和14个附着点。
  • 以Power Doppler评分≤1定义关节、腱旁组织、肌腱和附着点的最小超声疾病活动度(MUDA-j/e)。
  • 将灰阶与Power Doppler信息相加计算整体超声评分(GUIS-j/e)。

主要发现

  • 基线时LDA比例为33.7%-65.0%,随访时为44.3%-80.6%,取决于所用标准。
  • MUDA-j/e在基线时为16.9%,随访时为30%。
  • 基线和随访时,DAPSA与PASDAS定义的中/高疾病活动度患者GUIS-j/e显著高于LDA患者。
  • 随访时,DAPSA、PASDAS、CPDAI和MDA定义的中/高疾病活动度患者GUIS-j/e显著高于LDA患者。
  • 中/高疾病活动度患者中MUDA-j/e比例为基线8.1%-21.4%、随访8.3%-20.0%,取决于所用临床复合指标。

关键数值与推荐

  • DAPSA≤14、PASDAS≤3.2、CPDAI≤4、DAS28-CRP≤2.8及MDA标准用于判定LDA。
  • MUDA-j/e定义为Power Doppler评分≤1(关节、腱旁组织、肌腱和附着点)。

临床怎么用

  • 临床评估PsA低疾病活动度时,DAPSA、PASDAS、CPDAI和MDA可辅助反映超声活动度,DAS28-CRP不适用。
  • 对临床达标但疼痛明显者,应结合超声评估是否存在亚临床炎症。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate low disease activity (LDA) cut-offs in psoriatic arthritis (PsA) using ultrasound. METHODS: Eighty-three PsA patients underwent clinical and ultrasound examinations at two visits. LDA was assessed using the Disease Activity index for Psoriatic Arthritis (DAPSA ⩽ 14), the Psoriatic ArthritiS Disease Activity Score (PASDAS ⩽ 3.2), the Composite Psoriatic Disease Activity Index ⩽ 4, the DAS28-CRP ⩽ 2.8 and the minimal disease activity criteria. Ultrasound was performed at 68 joints and 14 entheses. Minimal ultrasound disease activity (MUDA-j/e) was defined as a Power Doppler score ⩽ 1, respectively at joints, paratendinous tissue, tendons and entheses. A global ultrasound score was calculated by summing Grey Scale and Power Doppler information (GUIS-j/e). RESULTS: LDA was present in 33.7-65.0% at baseline and in 44.3-80.6% at follow-up, depending on the criteria used. MUDA-j/e was observed in 16.9% at baseline and in 30% at follow-up. GUIS-j/e was significantly higher in patients with moderate/high disease activity vs LDA according to DAPSA and PASDAS at baseline and DAPSA, PASDAS, Composite Psoriatic Disease Activity Index and minimal disease activity at follow-up. Patients in moderate/high disease activity had MUDA-j/e in 8.1-21.4% at baseline and in 8.3-20.0% at follow-up, depending on the applied clinical composite. MUDA-j/e patients with moderate/high disease activity had higher levels of pain and pain-related items than those with LDA. CONCLUSION: The LDA cut-offs of DAPSA, PASDAS, Composite Psoriatic Disease Activity Index, minimal disease activity, but not DAS28-CRP are capable of distinguishing between high and low ultrasound activity. Pain and pain-related items are the main reason why PsA patients without signs of ultrasound inflammation are classified with higher disease activity.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Bosch P, Husic R, Ficjan A, et al. Evaluating current definitions of low disease activity in psoriatic arthritis using ultrasound. Rheumatology (Oxford). 2019. PMID: 31199483. doi:10.1093/rheumatology/kez237

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。