双能CT诊断痛风的系统评价与荟萃分析
基于患者的汇总敏感度为0.81(95%CI 0.77–0.86)、特异度为0.91(95%CI 0.85–0.95);基于关节/部位的汇总敏感度为0.83(95%CI 0.79–0.86)、特异度为0.88(95%CI 0.83–0.92)。在病程≤6周时,关节水平的汇总敏感度降至0.55(95%CI 0.46–0.64)、特异度为0.89(95%CI 0.84–0.94)。结论认为DECT在已确诊痛风中有较高诊断准确性,但在新近起病者中敏感度较低。
要点
- DECT在已确诊痛风中的诊断准确性较高,基于患者和基于关节的汇总敏感度与特异度均较高
- 病程≤6周时关节水平汇总敏感度仅0.55(95%CI 0.46–0.64),新近起病者诊断敏感度低
- 临床解读DECT阴性结果时需结合病程,早期痛风患者不应仅凭阴性DECT排除诊断
核心结论
- DECT在已确诊痛风患者中诊断准确性较高,但在新近起病(病程≤6周)患者中诊断敏感度较低。
研究设计与样本
- 参考标准为关节液评估发现单钠尿酸盐晶体或经验证的诊断标准组合,方法学质量按QUADAS-2标准评价。
- 基于患者和基于关节/部位的数据分别合并,并按疾病分期/病程及参考标准进行亚组分析。
主要发现
- 基于患者的汇总敏感度为0.81(95%CI 0.77–0.86),汇总特异度为0.91(95%CI 0.85–0.95)。
- 基于关节/部位的汇总敏感度为0.83(95%CI 0.79–0.86),汇总特异度为0.88(95%CI 0.83–0.92)。
- 病程≤6周时,关节水平的汇总敏感度为0.55(95%CI 0.46–0.64),汇总特异度为0.89(95%CI 0.84–0.94)。
关键数值与推荐
- DECT诊断痛风的参考标准为关节液评估发现单钠尿酸盐晶体或经验证的诊断标准组合。
- 基于患者的汇总敏感度0.81(95%CI 0.77–0.86)、特异度0.91(95%CI 0.85–0.95)。
- 基于关节/部位的汇总敏感度0.83(95%CI 0.79–0.86)、特异度0.88(95%CI 0.83–0.92)。
- 病程≤6周时关节水平汇总敏感度0.55(95%CI 0.46–0.64)、特异度0.89(95%CI 0.84–0.94)。
临床怎么用
- DECT可用于已确诊痛风患者的辅助诊断,其诊断准确性较高。
- 对病程≤6周的新近起病痛风患者,DECT阴性结果不能可靠排除痛风,需结合临床和关节液检查综合判断。
局限性
- 原文未报告纳入研究的具体样本量、各研究间异质性及发表偏倚评估结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study aimed to assess the utility of dual energy CT (DECT) for diagnosing gout. METHODS: A systematic literature search was performed in PubMed, EMBASE and Cochrane Library. Studies evaluating the utility of DECT for diagnosing gout were included. Reference standards were detection of monosodium urate crystals at SF assessment or a validated set of criteria. The methodological quality of studies was evaluated according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 criteria. Data from person-based and joint-/localization-based evaluations were pooled separately, and subgroup analyses for disease stage/duration and reference standard were performed. RESULTS: Ten studies were included; in person-based evaluations, the pooled (95% CI) sensitivity and specificity were 0.81 (0.77, 0.86) and 0.91 (0.85, 0.95), respectively. In joint-based evaluations, they were 0.83 (0.79, 0.86) and 0.88 (0.83, 0.92), respectively. At short disease duration (⩽6 weeks), the pooled (95% CI) sensitivity and specificity at the joint level were 0.55 (0.46, 0.64) and 0.89 (0.84, 0.94), respectively. CONCLUSION: DECT has a high diagnostic accuracy in established gout, but its diagnostic sensitivity is low in subjects with recent onset gout.
引用
- Gamala M, Jacobs JWG, van Laar JM, et al. The diagnostic performance of dual energy CT for diagnosing gout: a systematic literature review and meta-analysis. Rheumatology (Oxford). 2019. PMID: 31089688. doi:10.1093/rheumatology/kez180
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。