文献速递其他结缔组织病

唾液腺超声评分系统在干燥综合征中的视频片段评估:OMERACT超声工作组可靠性研究

Video clip assessment of a salivary gland ultrasound scoring system in Sjögren's syndrome using consensual definitions: an OMERACT ultrasound working group reliability exercise.
PubMed 文献 · Ann Rheum Dis · 2019-04-29

该研究通过三轮Delphi法制定原发性干燥综合征唾液腺超声定义与评分系统,并用视频片段测试读者内与读者间可靠性。读者内可靠性优秀(Cohen's kappa 0.81),读者间可靠性良好(Light's kappa 0.66)。

要点

  • 共识定义聚焦腮腺与颌下腺的灰阶病变,半定量评估无回声/低回声灶。
  • 读者内可靠性优秀(Cohen's kappa 0.81),读者间可靠性良好(Light's kappa 0.66)。

核心结论

  • 制定了原发性干燥综合征唾液腺超声新定义与半定量评分系统,视频片段测试显示读者内可靠性优秀、读者间可靠性良好。

研究设计与样本

  • 收集原发性干燥综合征与非干燥综合征口干患者的唾液腺超声视频片段,包含不同疾病严重程度,进行读者内与读者间可靠性测试。

主要发现

  • 在三对唾液腺中,共识同意评估腮腺和颌下腺。
  • 共识同意仅对灰阶病变进行评分,聚焦无回声/低回声灶的半定量评估,若不可行则对脂肪或纤维病变进行定性(存在/不存在)评估。
  • 检测和评分这些病变的读者内可靠性优秀(Cohen's kappa 0.81),读者间可靠性良好(Light's kappa 0.66)。

关键数值与推荐

  • 读者内可靠性Cohen's kappa为0.81。
  • 读者间可靠性Light's kappa为0.66。

临床怎么用

  • 该新定义与评分系统可用于原发性干燥综合征唾液腺超声的标准化评估,视频片段可作为可靠性培训与评估工具。

局限性

  • 可靠性测试基于视频片段而非实时超声检查,可能无法完全反映临床实际扫描的变异性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To develop ultrasound (US) definitions and a US novel scoring system for major salivary gland (SG) lesions in patients with primary Sjögren's syndrome (pSS) and to test their intrareader and inter-reader reliability using US video clips. METHODS: Twenty-five rheumatologists were subjected to a three-round, web-based Delphi process in order to agree on (1) definitions and scanning procedure of salivary gland ultrasonography (SGUS): parotid, submandibular and sublingual glands (PG, SMG and SLG); (2) definitions for the elementary SGUS lesions in patients with Sjögren's syndrome; (3) scoring system for grading changes. The experts rated the statements on a 1-5 Likert scale. In the second step, SGUS video clips of patients with pSS and non-pSS sicca cases were collected containing various spectrums of disease severity followed by an intrareader and inter-reader reliability exercise. Each video clip was evaluated according to the agreed definitions. RESULTS: Consensual definitions were developed after three Delphi rounds. Among the three selected SGs, US assessment of PGs and SMGs was agreed on. Agreement was reached to score only greyscale lesions and to focus on anechoic/hypoechoic foci in a semiquantitative matter or, if not possible on a qualitatively (present/absent) evaluation of fatty or fibrous lesions. Intrareader reliability for detecting and scoring these lesions was excellent (Cohen's kappa 0.81) and inter-reader reliability was good (Light's kappa 0.66). CONCLUSION: New definitions for developing a novel semiquantitative US score in patients with pSS were developed and tested on video clips. Inter-reader and intrareader reliabilities were good and excellent, respectively.

来源:Ann Rheum Dis,查看原文。版权归原作者所有。

引用

  1. Jousse-Joulin S, D'Agostino MA, Nicolas C, et al. Video clip assessment of a salivary gland ultrasound scoring system in Sjögren's syndrome using consensual definitions: an OMERACT ultrasound working group reliability exercise. Ann Rheum Dis. 2019. PMID: 31036626. doi:10.1136/annrheumdis-2019-215024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。