文献速递其他结缔组织病

特发性炎症性肌病中Mi-2α与Mi-2β自身抗体的检测比较

Autoantibodies to Mi-2 alpha and Mi-2 beta in patients with idiopathic inflammatory myopathy.
PubMed 文献 · Rheumatology (Oxford) · 2019-01-01

该研究纳入82例特发性炎症性肌病患者(57例皮肌炎、16例多发性肌炎、9例幼年皮肌炎),平行使用颗粒多分析物技术(PMAT)与线性免疫印迹(LIA)检测抗Mi-2抗体,并检测775例疾病与健康对照评估特异性,发现两种方法总体一致性良好,PMAT检测的抗Mi-2β抗体与皮肌炎表型关联更密切。

要点

  • PMAT与LIA检测抗Mi-2抗体的一致性kappa值为0.27-0.77,总体一致性良好。
  • PMAT检测的抗Mi-2β抗体与皮肌炎临床表型关联最密切。
  • PMAT检测抗Mi-2抗体在对照组的灵敏度为28.1%、特异性为99.6%。

核心结论

  • LIA与PMAT检测抗Mi-2抗体总体一致性良好,对自身抗体标准化有重要意义。
  • PMAT检测的抗Mi-2β抗体与皮肌炎临床表型关联更为密切。

研究设计与样本

  • 研究纳入82例特发性炎症性肌病患者,其中女性68例、男性14例,包括皮肌炎57例、多发性肌炎16例、幼年皮肌炎9例。
  • 所有样本平行使用PMAT(Inova Diagnostics,仅供研究用)与LIA(Euroimmun)检测,并检测775例疾病与健康对照评估PMAT的临床特异性。

主要发现

  • 至少一种检测阳性的样本共29例,其中LIA检测Mi-2β阳性24例、Mi-2α阳性5例,PMAT检测Mi-2阳性23例。
  • 不同方法间一致性kappa值为0.27-0.77。
  • 以LIA结果为参考进行ROC分析,PMAT对比LIA Mi-2α及LIA Mi-2β的曲线下面积值均较高。
  • 对照组775例中3例抗Mi-2阳性(均为低水平),得出灵敏度28.1%、特异性99.6%。

关键数值与推荐

  • 以LIA为参考的ROC分析中,PMAT对比LIA Mi-2α及LIA Mi-2β的曲线下面积值均较高。
  • PMAT检测抗Mi-2抗体在对照组的灵敏度为28.1%、特异性为99.6%。

临床怎么用

  • 抗Mi-2抗体检测对皮肌炎诊断有重要价值,PMAT检测的Mi-2β抗体与皮肌炎表型关联更密切,可辅助临床分型。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The objective of this study was to compare the results obtained from different assays for the detection of anti-Mi-2 antibodies, which are important markers in the diagnosis of DM. METHODS: The study included 82 patients (68 females/14 males), most of whom had DM (n = 57), followed by PM (n = 16) and juvenile DM (n = 9). All samples were tested using a novel particle-based multi-analyte technology (PMAT) (Inova Diagnostics, research use only) in parallel with a line immunoassay (LIA: Euroimmun). To assess clinical specificity for the PMAT assay, a total of 775 disease and healthy controls were tested. RESULTS: 29 samples were positive by at least one test for anti-Mi-2 antibodies. Of those, 24 were Mi-2β LIA+, five were Mi-2α LIA+ and 23 Mi-2 PMAT+. The comparison shows varying agreement between the different methods (kappa 0.27-0.77). When LIA results were used as reference for receiver operating characteristics analysis, high area under the curve values were found for both PMAT vs LIA Mi-2α and LIA Mi-2β. When analysing the results in the context of the myositis phenotype, PMAT associated closest with the DM phenotype. In the control group, 3/775 controls (all low levels) were anti-Mi-2+ resulting in a sensitivity and specificity of 28.1% and 99.6%, respectively. CONCLUSION: Overall, good agreement was found between LIA and PMAT for anti-Mi-2 antibodies, which is important for the standardization of autoantibodies. Anti-Mi-2β antibodies measured by PMAT tend be more highly associated with the clinical phenotype of DM.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Richards M, García-De La Torre I, González-Bello YC, et al. Autoantibodies to Mi-2 alpha and Mi-2 beta in patients with idiopathic inflammatory myopathy. Rheumatology (Oxford). 2019. PMID: 30938432. doi:10.1093/rheumatology/kez092

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。