焦磷酸钙沉积病患者髋关节受累:肌肉骨骼超声的潜力与局限
该研究纳入50例确诊焦磷酸钙沉积病(CPPD)患者和40例年龄、性别、体重指数匹配的疾病对照,评估超声(US)检测髋关节焦磷酸钙(CPP)晶体沉积的潜力。US在90.0%的CPPD患者至少1个髋关节发现CPP沉积,US与X线(CR)的敏感度分别为90%和86%,特异度分别为85%和90%,总一致率77.8%。结论支持US可作为检测髋关节CPP沉积的一线、敏感、安全且可靠的影像技术。
要点
- US在90.0%的CPPD患者至少1个髋关节检出CPP晶体沉积。
- CPP沉积更常见于髋臼唇纤维软骨(72%的髋)而非股骨头透明软骨(17%的髋)。
- US与CR敏感度分别为90%和86%,特异度分别为85%和90%,总一致率77.8%。
核心结论
- US是检测髋关节CPP晶体沉积的一线、敏感、安全且可靠的影像技术。
研究设计与样本
- 纳入50例确诊CPPD患者和40例年龄、性别、体重指数匹配的疾病对照,均在前6个月内接受髋关节CR检查。
- 对双侧髋关节行US检查,评估髋臼唇纤维软骨和股骨头透明软骨的CPP晶体沉积。
- 由两名独立放射科医生评估CR上的髋关节CPP晶体沉积。
主要发现
- US在45/50例CPPD患者(90.0%)至少1个髋关节发现提示CPP晶体沉积,在73/100个髋关节(73.0%)发现沉积。
- CPP晶体沉积在髋臼唇纤维软骨的检出率高于股骨头透明软骨(分别为72%和17%的CPPD患者髋关节)。
- US与CR的敏感度分别为90%和86%,特异度分别为85%和90%,总一致率为77.8%。
关键数值与推荐
- US检测髋关节CPP晶体沉积的敏感度为90%,特异度为85%。
- CR检测髋关节CPP晶体沉积的敏感度为86%,特异度为90%。
- US与CR的总一致率为77.8%。
临床怎么用
- 对于疑似CPPD患者,可考虑使用US作为一线影像学方法评估髋关节CPP晶体沉积。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To preliminarily explore the diagnostic potential of ultrasound (US) in detecting calcium pyrophosphate (CPP) crystal deposits at the hip joint in a cohort of patients with CPP deposition disease (CPPD) who were previously evaluated by conventional radiography (CR) and to assess the sensitivity and specificity as well as the agreement between US and CR in the evaluation of hip CPP crystal deposits. METHODS: Fifty consecutive patients with definite CPPD and 40 age/sex/body mass index-matched disease control subjects who had undergone hip CR within the previous 6 months were enrolled. Bilateral hip US examination was carried out to assess the presence of CCP crystal deposits at the acetabular labrum fibrocartilage and at the femoral head's hyaline cartilage. Two independent radiologists evaluated the presence of hip CPP crystal deposits on CR in both groups. RESULTS: US findings indicative of CPP crystal deposits were found in at least 1 hip in 45 of 50 patients with CPPD (90.0%) and in 73 of 100 hips (73.0%). CPP crystal deposits were more frequently found at the acetabular labrum fibrocartilage than at the femoral head's hyaline cartilage (72% and 17% of the hips in patients with CPPD, respectively). US and CR sensitivity was 90% and 86%, whereas US and CR specificity was 85% and 90%, respectively. Total agreement between the US and CR findings was 77.8%. CONCLUSION: Our results provide new evidence supporting US as a first-line, sensitive, safe, and reliable imaging technique in detecting CPP crystal deposits at the hip level.
引用
- Di Matteo A, Filippucci E, Cipolletta E, et al. Hip Involvement in Patients With Calcium Pyrophosphate Deposition Disease: Potential and Limits of Musculoskeletal Ultrasound. Arthritis Care Res (Hoboken). 2019. PMID: 30474924. doi:10.1002/acr.23814
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。