引入一种基于磁共振成像的新型评分系统评估幼年皮肌炎患儿疾病活动度
研究开发并评估了一种基于MRI的新型评分系统(JIS),用于报告疑似幼年皮肌炎(JDM)患儿MRI表现的严重程度。9名儿科放射科顾问医师对40幅轴位和30幅冠状位大腿MRI图像独立进行两次评分,计算观察者间和观察者内信度。结果显示观察者间信度良好(轴位ICC=0.87-0.88,冠状位ICC=0.90),观察者内信度良好(ICC=0.90-0.94)。结论认为JIS是一种半客观评分系统,有潜力作为JDM患儿疾病严重程度和治疗反应的可信生物标志物。
要点
- JIS评分范围0(正常)至100(严重),用于评估疑似JDM患儿大腿MRI表现。
- 观察者间信度良好:轴位左肢ICC=0.88(95%CI:0.82,0.92),右肢ICC=0.87(95%CI:0.81,0.92)。
- 观察者间信度良好:冠状位左肢ICC=0.90(95%CI:0.85,0.95),右肢ICC=0.90(95%CI:0.84,0.94);观察者内ICC=0.90-0.94。
核心结论
- JIS是一种半客观评分系统,有潜力作为JDM患儿疾病严重程度和治疗反应的可信生物标志物。
研究设计与样本
- 研究纳入疑似JDM患儿的40幅轴位和30幅冠状位大腿MRI图像,由9名儿科放射科顾问医师独立进行两次评估和评分。
- 使用幼年皮肌炎磁共振成像评分(JIS)对每次读片的每个平面和每个肢体计算评分,评分范围0(正常)至100(严重)。
- 采用组内相关系数(ICC)分别通过双向和单向随机效应模型计算观察者间和观察者内一致性。
主要发现
- 轴位图像观察者间信度良好:左肢JIS范围46.8至61.0,ICC=0.88(95%CI:0.82,0.92);右肢JIS范围47.9至61.4,ICC=0.87(95%CI:0.81,0.92)。
- 冠状位图像观察者间信度良好:左肢JIS范围56.7至65.1,ICC=0.90(95%CI:0.85,0.95);右肢JIS范围55.7至66.8,ICC=0.90(95%CI:0.84,0.94)。
- 观察者内信度良好,ICC范围为0.90至0.94。
关键数值与推荐
- JIS评分范围0(正常)至100(严重),用于报告MRI表现的严重程度。
- 观察者间信度:轴位左肢ICC=0.88(95%CI:0.82,0.92),右肢ICC=0.87(95%CI:0.81,0.92);冠状位左肢ICC=0.90(95%CI:0.85,0.95),右肢ICC=0.90(95%CI:0.84,0.94)。
- 观察者内信度:ICC范围为0.90至0.94。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: We aimed to develop and assess the reliability of a novel MRI-based scoring system for reporting the severity of MRI findings in children with suspected JDM. METHODS: Nine consultant paediatric radiologists independently assessed and scored 40 axial and 30 coronal thigh MR images of children with suspected JDM on two occasions using the juvenile dermatomyositis magnetic resonance Imaging Score (JIS). JIS was calculated for both reads for each plane and each limb, with possible scores ranging from 0 (normal) to 100 (severe). Inter- and intraobserver agreement was calculated using the intraclass correlation coefficient (ICC) and two- and one-way random effects models, respectively. Bland-Altman plots of the difference in JIS against the average JIS were also produced for each rater. RESULTS: Overall, the interobserver reliability and agreement was good-for axial images, JIS ranged from 46.8 to 61.0 [ICC = 0.88 (95% CI: 0.82, 0.92)] for the left limb and 47.9-61.4 [ICC = 0.87 (95% CI: 0.81, 0.92)] for the right limb. For coronal images, JIS ranged from 56.7 to 65.1 [ICC = 0.90 (95% CI: 0.85, 0.95)] for the left limb and 55.7 to 66.8 [ICC = 0.90 (95% CI: 0.84, 0.94)] for the right limb. The intraobserver reliability and agreement was good, with ICC ranging from 0.90 to 0.94. CONCLUSION: JIS is a semi-objective scoring system with potential to serve as a reliable biomarker of disease severity and response to therapeutic interventions in children with JDM.
引用
- Thyoka M, Adekunle O, Pilkington C, et al. Introduction of a novel magnetic resonance imaging-based scoring system for assessing disease activity in children with juvenile dermatomyositis. Rheumatology (Oxford). 2018. PMID: 29901756. doi:10.1093/rheumatology/key144
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。