文献速递类风湿关节炎

超声检测的腱鞘炎与关节滑膜炎对类风湿关节炎稳定缓解期患者复发的预测作用:意大利风湿病学会超声研究组多中心研究STARTER研究结果

The predictive role of ultrasound-detected tenosynovitis and joint synovitis for flare in patients with rheumatoid arthritis in stable remission. Results of an Italian multicentre study of the Italian Society for Rheumatology Group for Ultrasound: the STARTER study.
PubMed 文献 · Ann Rheum Dis · 2018-06-09

意大利25个中心纳入361例临床缓解的类风湿关节炎患者,在基线、6个月和12个月进行临床评估与能量多普勒超声评估手腕部关节及腱鞘。12个月随访中98/326(30.1%)患者出现疾病复发,能量多普勒阳性腱鞘炎与关节滑膜炎同时存在可预测复发,粗分析OR为2.75(95%CI 1.45至5.20),校正分析OR为2.09(95%CI 1.06至4.13)。超声变量未预测功能恶化或影像学进展,超声能预测12个月复发但不能预测6个月复发。

要点

  • 能量多普勒阳性腱鞘炎与关节滑膜炎同时存在是临床缓解期类风湿关节炎复发的独立危险因素。
  • 粗分析OR为2.75(95%CI 1.45至5.20),校正分析OR为2.09(95%CI 1.06至4.13)。
  • 超声变量未预测功能恶化或影像学进展,超声能预测12个月复发但不能预测6个月复发。

核心结论

  • 能量多普勒阳性腱鞘炎与关节滑膜炎同时存在是临床缓解期类风湿关节炎患者复发的独立危险因素。
  • 肌肉骨骼超声评估是监测临床缓解期类风湿关节炎患者并辅助决策的有价值工具。

研究设计与样本

  • 意大利风湿病学会超声研究组推动的多中心纵向研究,25个意大利中心参与,连续纳入临床缓解的类风湿关节炎患者。
  • 所有患者在入组时、6个月和12个月接受完整临床评估(人口学数据、疾病特征、实验室检查、28关节临床评估及患者/医生报告结局)和手腕部腕关节、掌指关节、近端指间关节及手与腕部滑膜腱的能量多普勒超声评估。
  • 采用单变量和校正logistic回归模型评估临床与超声变量与复发、残疾及影像学进展的关联。

主要发现

  • 共纳入361例患者,平均年龄56.20(±13.31)岁,其中261例为女性,平均病程9.75(±8.07)年。
  • 12个月随访中,98/326(30.1%)例患者出现疾病复发。
  • 能量多普勒阳性腱鞘炎与关节滑膜炎同时存在可预测疾病复发,粗分析OR为2.75(95%CI 1.45至5.20),校正分析OR为2.09(95%CI 1.06至4.13)。
  • 超声变量未预测功能恶化或影像学进展。
  • 超声能预测12个月复发但不能预测6个月复发。

关键数值与推荐

  • 能量多普勒阳性腱鞘炎与关节滑膜炎同时存在预测疾病复发:粗分析OR 2.75(95%CI 1.45至5.20),校正分析OR 2.09(95%CI 1.06至4.13)。

临床怎么用

  • 原文结论指出肌肉骨骼超声评估是监测临床缓解期类风湿关节炎患者并辅助决策的有价值工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To define the role of ultrasound (US) for the assessment of patients with rheumatoid arthritis (RA) in clinical remission, including joint and tendon evaluation. METHODS: A multicentre longitudinal study has been promoted by the US Study Group of the Italian Society for Rheumatology. 25 Italian centres participated, enrolling consecutive patients with RA in clinical remission. All patients underwent complete clinical assessment (demographic data, disease characteristics, laboratory exams, clinical assessment of 28 joints and patient/physician-reported outcomes) and Power Doppler (PD) US evaluation of wrist, metacarpalphalangeal joints, proximal interphalangeal joints and synovial tendons of the hands and wrists at enrolment, 6 and 12 months. The association between clinical and US variables with flare, disability and radiographic progression was evaluated by univariable and adjusted logistic regression models. RESULTS: 361 patients were enrolled, the mean age was 56.20 (±13.31) years and 261 were women, with a mean disease duration of 9.75 (±8.07) years. In the 12 months follow-up, 98/326 (30.1%) patients presented a disease flare. The concurrent presence of PD positive tenosynovitis and joint synovitis predicted disease flare, with an OR (95% CI) of 2.75 (1.45 to 5.20) in crude analyses and 2.09 (1.06 to 4.13) in adjusted analyses. US variables did not predict the worsening of function or radiographic progression. US was able to predict flare at 12 months but not at 6 months. CONCLUSIONS: PD positivity in tendons and joints is an independent risk factor of flare in patients with RA in clinical remission. Musculoskeletal ultrasound evaluation is a valuable tool to monitor and help decision making in patients with RA in clinical remission.

来源:Ann Rheum Dis,查看原文。版权归原作者所有。

引用

  1. Filippou G, Sakellariou G, Scirè CA, et al. The predictive role of ultrasound-detected tenosynovitis and joint synovitis for flare in patients with rheumatoid arthritis in stable remission. Results of an Italian multicentre study of the Italian Society for Rheumatology Group for Ultrasound: the STARTER study. Ann Rheum Dis. 2018. PMID: 29886430. doi:10.1136/annrheumdis-2018-213217

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。