文献速递痛风与晶体性关节病

简报:已确诊痛风患者痛风发作定义的外部验证

Brief Report: Validation of a Definition of Flare in Patients With Established Gout.
PubMed 文献 · Arthritis Rheumatol · 2018-02-06

在17个国际中心509例痛风患者的横断面研究中,对痛风发作临时定义进行外部验证,由当地风湿免疫科专家独立裁定发作状态。需满足4项标准中至少3项的定义敏感度85%、特异度95%、准确率92%,ROC曲线下面积0.97,该定义已被验证为敏感、特异且准确。

要点

  • 需满足4项标准中至少3项的定义敏感度85%、特异度95%、准确率92%。
  • 4项标准为:患者自述痛风发作、静息痛评分>3分(0-10分)、至少1个关节肿胀、至少1个关节发热。
  • 基于分类回归树算法的定义(入口:静息痛评分>3分,随后患者自述发作「是」)敏感度73%、特异度96%。

核心结论

  • 需满足4项患者报告标准中至少3项的定义已被验证为对痛风发作敏感、特异且准确,验证基于独立的大型国际患者样本。
  • 经验证的痛风发作定义将改善痛风研究中重要临床结局的确认。

研究设计与样本

  • 横断面研究,在17个国际中心的常规临床诊疗访视中纳入509例痛风患者。
  • 收集数据以按临时定义将患者分类为经历或未经历痛风发作,由当地专家风湿免疫科医生对痛风发作状态进行最终独立裁定。

主要发现

  • 患者平均±标准差年龄为57.5±13.9岁,89%为男性。
  • 需满足4项标准中至少3项的定义确认痛风发作的敏感度为85%、特异度为95%、准确率为92%。
  • ROC曲线下面积为0.97。
  • 基于分类回归树算法的定义(入口:静息痛评分>3分,随后患者自述发作「是」)敏感度为73%、特异度为96%。

关键数值与推荐

  • 需满足4项标准中至少3项:患者自述痛风发作、静息痛评分>3分(0-10分数字评定量表)、至少1个关节肿胀、至少1个关节发热。
  • 该定义敏感度85%、特异度95%、准确率92%,ROC曲线下面积0.97。
  • 分类回归树算法定义:入口为静息痛评分>3分,随后患者自述发作「是」,敏感度73%、特异度96%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To perform external validation of a provisional definition of disease flare in patients with gout. METHODS: Five hundred nine patients with gout were enrolled in a cross-sectional study during a routine clinical care visit at 17 international sites. Data were collected to classify patients as experiencing or not experiencing a gout flare, according to a provisional definition. A local expert rheumatologist performed the final independent adjudication of gout flare status. Sensitivity, specificity, predictive values, and receiver operating characteristic (ROC) curves were used to determine the diagnostic performance of gout flare definitions. RESULTS: The mean ± SD age of the patients was 57.5 ± 13.9 years, and 89% were male. The definition requiring fulfillment of at least 3 of 4 criteria (patient-defined gout flare, pain at rest score of >3 on a 0-10-point numerical rating scale, presence of at least 1 swollen joint, and presence of at least 1 warm joint) was 85% sensitive and 95% specific in confirming the presence of a gout flare, with an accuracy of 92%. The ROC area under the curve was 0.97. The definition based on a classification and regression tree algorithm (entry point, pain at rest score >3, followed by patient-defined flare "yes") was 73% sensitive and 96% specific. CONCLUSION: The definition of gout flare that requires fulfillment of at least 3 of 4 patient-reported criteria is now validated to be sensitive, specific, and accurate for gout flares, as demonstrated using an independent large international patient sample. The availability of a validated gout flare definition will improve the ascertainment of an important clinical outcome in studies of gout.

来源:Arthritis Rheumatol,查看原文。版权归原作者所有。

引用

  1. Gaffo AL, Dalbeth N, Saag KG, et al. Brief Report: Validation of a Definition of Flare in Patients With Established Gout. Arthritis Rheumatol. 2018. PMID: 29161469. doi:10.1002/art.40381

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。