文献速递类风湿关节炎

类风湿关节炎骨侵蚀在HR-pQCT中的分割方法比较

Methods for segmentation of rheumatoid arthritis bone erosions in high-resolution peripheral quantitative computed tomography (HR-pQCT).
PubMed 文献 · Semin Arthritis Rheum · 2017-09-23

该研究比较了三种分割技术(手工半椭球公式法、半自动mESE和半自动MIAF软件)在测量ACPA阳性RA患者掌指关节HR-pQCT骨侵蚀体积中的表现。mESE与MIAF一致性良好,而手工半椭球公式法低估侵蚀体积,尤其对较大侵蚀。不规则侵蚀在所有方法中均大于规则侵蚀。

要点

  • mESE与MIAF在测量侵蚀体积时一致性良好,手工半椭球公式法会低估侵蚀大小。
  • 不规则侵蚀的体积显著大于规则侵蚀,且球形度随侵蚀增大而降低。
  • MIAF和mESE可量化侵蚀体积且不受形状影响,适合评估RA关节结构损伤。

核心结论

  • MIAF和mESE对RA炎性骨侵蚀的分割具有优异的读者间可靠性,可独立于侵蚀形状计算体积。

研究设计与样本

  • 研究纳入65例ACPA阳性RA患者(46女/19男),中位年龄57岁,中位病程6.1年,中位DAS28为2.8,对掌指关节行HR-pQCT扫描。
  • 共分析76处侵蚀,采用三种分割技术:手工半椭球公式法、半自动mESE和半自动MIAF软件,并用Bland-Altman图描述方法间一致性。

主要发现

  • mESE与MIAF在侵蚀大小测量中显示良好一致性,而手工半椭球公式法低估侵蚀体积,尤其对较大侵蚀。
  • 三种方法中不规则侵蚀均大于规则侵蚀:MIAF为19.7 vs 3.4 mm³,mESE为15.5 vs 2.3 mm³,手工法为7.2 vs 1.52 mm³,均p<0.001。
  • MIAF测量的侵蚀球形度随侵蚀增大而显著降低(p<0.001)。

关键数值与推荐

  • 不规则侵蚀与规则侵蚀体积比较:MIAF 19.7 vs 3.4 mm³,mESE 15.5 vs 2.3 mm³,手工法7.2 vs 1.52 mm³,所有p<0.001。

临床怎么用

  • 在RA患者HR-pQCT评估中,优先选用MIAF或mESE分割骨侵蚀以准确量化体积,避免手工半椭球公式法对较大侵蚀的低估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The comparison between different techniques to quantify the 3-dimensional size of inflammatory bone erosions in rheumatoid arthritis(RA) patients. METHODS: Anti-cyclic citrullinated peptide antibody(ACPA) positive RA patients received high-resolution peripheral quantitative computed tomography (HR-pQCT) scans of the metacarpophalangeal joints (MCP). Erosions were measured by three different segmentation techniques: (1) manual method with calculation by half-ellipsoid formula, (2) semi-automated modified Evaluation Script for Erosions (mESE), and (3) semi-automated Medical Image Analysis Framework (MIAF) software. Bland & Altman plots were used to describe agreement between methods. Furthermore, shape of erosions was classified as regular or irregular and then compared to the sphericity obtained by MIAF. RESULTS: A total of 76 erosions from 65 RA patients (46 females/19 males), median age 57 years, median disease duration 6.1 years and median disease activity score 28 of 2.8 units were analyzed. While mESE and MIAF showed good agreement in the measurement of erosion size, the manual method with calculation by half-ellipsoid formula underestimated erosions size, particularly with larger erosions. Accurate segmentation is particularly important in larger erosions, which are irregularly shaped. In all three segmentation techniques irregular erosions were larger in size than regular erosions (MIAF: 19.7 vs. 3.4mm3; mESE: 15.5 vs. 2.3mm3; manual = 7.2 vs. 1.52mm3; all p < 0.001). In accordance, sphericity of erosions measured by MIAF significantly decreased with their size (p < 0.001). CONCLUSION: MIAF and mESE allow segmentation of inflammatory bone erosions in RA patients with excellent inter reader reliability. They allow calculating erosion volume independent of erosion shape and therefore provide an attractive tool to quantify structural damage in individual joints of RA patients.

来源:Semin Arthritis Rheum,查看原文。版权归原作者所有。

引用

  1. Figueiredo CP, Kleyer A, Simon D, et al. Methods for segmentation of rheumatoid arthritis bone erosions in high-resolution peripheral quantitative computed tomography (HR-pQCT). Semin Arthritis Rheum. 2017. PMID: 29122245. doi:10.1016/j.semarthrit.2017.09.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。